10.17
MMC-Recorder menue
With the assistance of the memory card it is possible to make measurements on the frequency inverter
without notbook. the measurement will be con
fi
gurated in the
MMC-Recorder
menu.
Parameter
Description
Value range
Factory set-
ting
REC_MOD
Recorder settings
Off:
Recorder is switched off
ON:
Recorder ist active, the operating curves are saved to the
memory card
Stop&Shot:
Manual stopping and saving of a measurement
which was started with MOD=ON". After saving the data on the
memory card, REC_MOD will set to "Off".
ZETAMON:
Mode for using ZETAMON software
The settings for REC_MOD can only be changed with
REC_CFG=0.
Off
On
Stop&Shot
ZETAMON
ZETAMON
REC_CFG
Con
fi
guring the measurement channels
0:
all measurement channels and the recording time can be
freely con
fi
gured
1
…
9:
permanently set con
fi
gurations that cannot be modi
fi
ed
0
1
2
3
4
5
6
7
8
9
1
REC_NUM
Directory number
Number assignment for the
fi
le on the memor card. With entering
"0" the serial number of the inverter will be used for the name of
the
fi
le.
0
TRIG_BY
Trigger-source
Speci
fi
cations for stopping the recorder and saving the data to
the memory card.
Error:
data will be saved as soon as an error occurs
Err/stop:
data will be saved as soon as an error occurs or an
error-free travel is
fi
nished
Error
Error/Stop
1.0
T_REC
Record-time
Time for 1000 measurements
For a recording time of 5 s, for example, measured values are
recorded every 5 ms
5 s
10 s
15 s
20 s
40 s
80 s
160 s
0.5 h
1 h
24 h
5
T_DLY
Trigger Delay
Delay time for stopping of the masurement, e.g. T_DLY=0.5s:
the recording will be stopped 0.5s after an error occurs.
0.5 s
0.5 s
Original operating instructions
ZETADYN 3C
Parameter list
R-TBA08_03-GB 1619
Part.-No. 00163322-GB