10.25
INFO menu
The
INFO menu
provides an easily accessible overview of:
•
Current measurements
•
Current operation conditions of the inverter
•
Current switching states of the inputs and outputs
•
Inverter internal measurements
•
Information about the internal components
The individual pages are numbered for increased clarity.
Serial No. - - - - - - -
01
ZETADYN 3BF013-A
SN: 06128238/x001
3.24-110308xx
Page 01: Serial-No.
Line 2:
Indication of the inverter type and inverter size
-A: Typ ZETADYN 3BF for asynchronous motors
-S: Typ ZETADYN 3BF f
ü
r synchronous motors
-SD:Typ ZETADYN 3C with integrated brake contactors for synchronous machines
-X: unknown type
Line 3:
Serial number/type consecutively numbered
/0xxx: type ZETADYN 3BF
/Dxxx:Type ZETADYN 3C with integrated brake contactors for synchronous machines
Line 4:
Software version
Loaded 3rd operating language
Status - - - - - - - - - -
02
"
System OFF
3
530
R
540
R
550
R
560
R
100
^0.00 0.00 0.00m/s
Page 02: Status
Line 2:
current service condition in plain text display
Line 3:
last 5 service conditions
current operating condition is displayed on right
in total, the last 60 service conditions can be inquired:
Previous page
Next page
The current condition will be indicated with the arrows > <
The previous conditions are indicated with the arrows < >
Line 4 (from left to right):
current direction of travel
current position of car in the shaft
current travel path with positioning speed
current traveling speed
Dist. - - - - - - - - - - -
03
sa: 0.00 s21: 0.52m
sr:^0.00 s31: 1.45m
s1: 0.00 sd: 0.52m
Page 03: Dist
Line 2:
sa: current position of car in the shaft
s21: calculated deceleration path V_2
R
V_1
s20: calculated deceleration path V_2
R
Standstill (only in DCP02/DCP04)
Line 3:
sr: current direction of travel, current total route
s31: calculated deceleration path V_3
R
V_1
s30: calculated deceleration path V_3
R
Standstill (only in DCP02/DCP04)
Line 4:
s1: current travel path with positioning speed V_1 (not used in DCP02 / DCP04)
sd:real deceleration path V_3
R
V_1 or V_2
R
V_1
The display can be frozen by pressing the button.
Original operating instructions
ZETADYN 3C
Parameter list
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
99/204