10.21
Power section menu
Con
fi
guring the tolerances of the internal power stage.
Parameter
Description
Value range
Factory set-
ting
M_PWM
Pulse width modulation operating mode
Auto:
PWM frequency is changed depending on the power
stage temperature and load.
At the start of travel, the motor voltage is cycled at the cycle
frequency set in parameter "f_PWM_H".
Cycle frequency is reduced if required.
Fix f_PWM:
motor voltage is permanently cycled at the PWM
frequency set in the parameter "f_PWM"
Auto
Fix f_PWM
Auto
f_PWM
Cycle frequency at parameter setting "M_PWM=Fix f_PWM"
2.5 ... 10.0 kHz
8.0
f_PWM_H
Maximum cycle frequency (start frequency) at parameter setting
"M_PWM=Auto"
Parameter is only shown for "M_PWM=Auto".
2.5 ... 16.0 kHz
16.0
UDC_N
DC voltage for the DC-link
100 ... 600 V
565
UDC_MIN
Minimum limit value of the DC-link voltage
30 ... 500 V
450
UDC_MAX
Maximum limit value of the DC-link voltage
300 ... 800 V
760
FAN_T
Power stage temperature at which the fan is switched on
28 ... 45
°
C
33
10.22
Menu checks
Selection of supporting tests during acceptance of the system:
•
Testing of the protection device according to EN81-A3
Parameter
Description
Value range
Factory set-
ting
SCY_EN
Enabling of the test functions
On:
Functions are accessible
Off:
No access to the functions
After a test function has been performed, this parameter
automatically adopts the "Off" value.
On
Off
Off
SCY_A3
Testing the protection device according to EN81-A3 for protec-
tion against accidental movement of the car
No current:
Movement of the car by releasing the brakes with-
out power to the
fi
nal stage
Off:
Function deactivated
No current
Off
Off
10.23
CAN menu
Parametrize the CAN-speci
fi
c functions.
Parameter
Description
Value range
Factory set-
ting
LIFT_NR
Enter the lift number
1 ... 2
1
NODE_ID
Node number, normally:
Control system: 1
Frequency inverter: 2
Encoder: 4
1 ... 128
2
BD_RATE
Bitrate
10 kBd ... 250 kBd
250 kBd
MODE
Operation mode of the ZETADYN 3
Position / Velocity
Position
T_CMD
Maximum waiting time for commands of the control system
200 ... 3000 ms
1500 ms
Original operating instructions
ZETADYN 3C
Parameter list
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
97/204