Parameter
Description
Value range
Factory set-
ting
f_O1
Con
fi
guration of the function of the digital outputs O1
…
O4
under "CONFIG=free" (For description of the functions, see
table)
Off
MotContact
RB-Invers
V<V_G1
V<V_G2
V<1.1*V_3
Warning
Err
EVAC.Dir
MB_Brake
INV V<V_G1
INV V<V_G2
V=0
PFU
Info rope
TD_CNT ext.
ZR_EN
Err
f_O2
MB_Brake
f_O3
MotContact
f_O4
V < V_G1
f_PWM
Con
fi
guration of the function of the digital output PWM
ATTENTION!
The PWM output does not have zero potential.
The GND potential of the internal 24 V mains supply is con-
nected!
V_G1
Presetting of the limit value 1 when using the V<V_G1 parame-
ter for a digital output
0.03 ... 3.20 m/s
0.30
V_G2
Presetting of the limit value 2 when using the V<V_G2 parame-
ter for a digital output
0.03 ... 3.20 m/s
0.80
V_G3
Presetting of the limit value 3 (this information is only issued
when using a DCP protocol)
0.03 ... 3.20 m/s
0.50
SIM_V1
ON:
Distance-dependent delay of V3 -> V1 or V2 -> V1 is carried
out if V1 is activated 100 ms after switching off V3 or V2 at the
latest
SIM_V1 must be activated to carry out a distance-dependent
delay of V3 -> V1 or V2 -> V1 with binary speed speci
fi
cation
Off:
Distance-dependent delay of V3 -> V1 or V2 -> V1 is only
carried out if the positioning speed is already activated at the
time of deactivation of a high travelling speed (V3 or V2)
On
Off
Off
A_MAX
Delay in elevator emergency stop due to deactivation of the
input with the function "/DELAY"
1.00 m/s
2
S_B_OFF
Additional braking offset
If the control system doesn't extend early enough, it can be
increased here
50 ... 160 mm
50