15.5.1.3
Error
fl
ash code during a software update
If an error occurs during the software update, a
fl
ash code is issued by LED OP1 for the corresponding
error message.
1
5
4
3
2
1
Quickly
fl
ashing (10 pulses/s)
2
Break (1 s)
3
Slowly
fl
ashing (Number of pulses corresponds to the error message in the table below)
4
Break (s)
5
Cycle is repeated
Number of
pulses
Error description
1
EEPROM is missing
2
The memory card does not contain a software update
3
The update software on the memory card is identical with the software in the frequency
inverter
4
The memory card does not contain a valid software update
5
The
fi
les in the update software are identical
6
External application-processor RAM is defective
8,14
Internal programing voltage does not switch on
8,19
Internal programing voltage does not switch off
(it is possible that the prog. key is blocked)
16
Error while deleting the program memory (
fl
ash delete error)
17
Error while writing the program memory (Flash write error)
(Flash write error)
18
Error while checking the written
fi
les in the program memory (
fl
ash data error)
23
Memory card was removed too early
15.5.2
Saving parameters
The parameters of an inverter can be saved on the memory card.
Information
Only the parameters of
one
inverter can be saved on the memory card. It is not possible to save the
parameters of several inverters.
Statistics
->Memory Card
MMC Recorder
Encoder-adjust.
Select
"Memory Card"
menu
Con
fi
rming menu selection
Memory Card
|
-
"
SAV_PAR OFF
|
-
"
ON
Select
"SAV_PAR"
parameter
Con
fi
rming menu selection
Select "SAV_PAR=EIN"
Con
fi
rm with the key.
Please wait ...
Copy1:_ _ _ _ _ _ _
The parameters are saved.
Original operating instructions
ZETADYN 3C
Special functions
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
172/204