15.2.5
Alignment absolute encoder type ERN1387
The calibration of absolute value encoders of type ERN1387 corresponds to calibration with brake
closed.
Information
To minimize inaccuracies in determination of position, the encoder calibration must be performed
4
times
with the brake closed!
The traction sheave needs to be turned through approx. 90
°
after every calibration.
Positions for the encoder alignment
Carry out encoder calibration type ERN1387
* Result: 2.7A
144-228 -> 186/ 6
ENC_OFF= 6 [END]
Perform encoder calibration 4 times with brake closed.
Note the value for ENC_OFF after each calibration
Calculating the average offset
Encoder-adjust.
|
-
"
ENC_OFF 6.00 DEG
|
-
"
6.00
Encoder Offset
Enter mean offset in parameter
"ENC_OFF"
in the menu
"Encoder-adjust"
Original operating instructions
ZETADYN 3C
Special functions
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
165/204