10.19
Safety gear menu
Con
fi
guration of the data used for the "Safety gear" function.
The procedure for the safety brake is described in the "Special functions" chapter.
Parameter
Description
Value range
Factory set-
ting
SB_MOD
Activate or deactivate the capture release
OFF:
Capture release is deactivated
On:
Starting the Safety-Brake-function in the requested direction
by pressing the button "Inspection trip UP" oder "Inspection trip
DOWN"
On
Off
Off
SB_M
Default for pulse amplitude with which the motor is to be fed with
current.
The default is made as a percent from the maximum inverter
operating current (rated current x 1.8)
10 ... 100 %
70
SB_T0
Pulse breake
Break time between the individual current pulses
0.1 ... 2.0 s
0.2
SB_T1
Î
mpulse time
Time for which the motor will be fed with current
0.1 ... 1.0 s
0.5
SB_N
Number of current pulses
1 ... 5
3
1
SB_M [%]
100
SB_N=3
SB_T1
SB_T0
t
Process capture release
1
Inspection trip "UP" or "DOWN"
10.20
HW-Ident. menu
Identi
fi
cation of the individual assemblies in the frequency inverter. The identi
fi
cation of the assembly
is generally downloaded directly from its EEPROM.
Manual input of the identi
fi
cation defaults is only necessary in case of malfunctions and replacements.
To do so, enter the stored version number for the corresponding assembly.
If the number of the stored version numbers is exceeded, a 0 = automatic identi
fi
cation is entered.
Parameter
Description
Value range
Factory set-
ting
ID_NOK
The number of the changed hardware identi
fi
ca-
tion (identi
fi
cation-no. unequal 0) is indicated
Original operating instructions
ZETADYN 3C
Parameter list
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
96/204