15.5.5
Performing measurements
It is possible to perform measurements on the frequency inverter. These measurements are con
fi
g-
ured in the
MMC-Recorder
menu and can be saved on the memory card. A description of the
individual parameters of the
MMC-Recorder
menu can be found in the chapter "Parameter List /
Men
ü
MMC-Recorder". The following folder structure is created on the memory card:
"3BF\DEVICE\-
serial number\Rec"
. A sub-folder is created in the "Rec" folder for every measuring variant. The
measurements are saved in these sub-folders. The following sub-folders can be created:
•
"ERR"
folder: Save measurements which were interrupted by occurrence of an error.
•
"NORM"
folder: Save measurements for runs without errors.
•
"SHOT"
folder: Save measurements which were made with the "Stop&Shot" function.
The actual number of runs is used as a
fi
le name (e.g. "00000109.ZR3" for 109 runs).
15.5.6
Saving con
fi
gurations
The con
fi
gurations of parameters can be saved on the memory card by allocating con
fi
guration
numbers. The parameter list and the printer list are saved. The following folder structure is created on
the memory card:
"3BF\CONFIG\con
fi
guration number"
. Parameter lists are saved with the
fi
le
extension ".PA3" and printer lists with the
fi
le extension ".PRT".
Information
If two con
fi
gurations are saved under the same con
fi
guration number, the existing con
fi
guration is
overwritten.
Statistics
->Memory Card
MMC Recorder
Encoder-adjust.
Select
"Memory Card"
menu
Con
fi
rming menu selection
Memory Card
|
-
"
SAV_CFG 0
|
-
"
1
Select
"SAV_CFG"
parameter
Con
fi
rming menu selection
Line 3:
Enter con
fi
guration number ("1" in this example)
Con
fi
rm with the key.
Copy1:
_ _ _ _ _ _ _ _ _
The parameter list and the printer list are saved.
Memory Card
UPDATE 0
-> SAV_CFG 0
LOD_CFG 0
After the data backup the
"Memory Card"
menu is displayed again.
Original operating instructions
ZETADYN 3C
Special functions
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
174/204