![background image](http://html1.mh-extra.com/html/zeiss/axioskop-40/axioskop-40_operating-manual_3382221027.webp)
Axioskop 40
INSTRUMENT DESCRIPTION
Axioskop 40 FL
Technical data
Carl Zeiss
B 40-810 e 12/01
1-13
1.7
Technical data
Dimensions (width x depth x height)
Axioskop 40 stand ........................................................................ approx. 280 mm x 560 mm x 505 mm
Axioskop 40 FL stand with HBO 100
and adjustable ergo-tube 20°/23 in highest setting........................ approx. 280 mm x 730 mm x 555 mm
Weight
Axioskop 40 ...................................................................................................................... approx. 15 kg
Axioskop 40 FL with HBO 100......................................................................................... approx. 19.5 kg
Ambient conditions
Storage and transport (in packaging)
Permissible ambient temperature ...................................................................................... -10 to + 50 °C
Permissible relative humidity ............................................................................. 20 % to 75 % at +35 °C
Atmospheric pressure ............................................................................................. 800 hPa to 1060 hPa
Operation
Permissible ambient temperature ..................................................................................... +10 to + 35 °C
Permissible relative humidity ............................................................................. 20 % to 75 % at +35 °C
Atmospheric pressure ............................................................................................. 800 hPa to 1060 hPa
Altitude.............................................................................................................................. max. 2000 m
Pollution degree ................................................................................................................................... 2
Operating data
Operating environment.......................................................................................................... clean room
Protection class.......................................................................................................................................I
Protection type ................................................................................................................................IP 20
Electrical safety............................................................. in compliance with DIN EN 61010-1 (IEC 1010-1)
including CSA and UL directives
Overvoltage category.............................................................................................................................II
Radio interference suppression....................................................... in accordance with EN 55011, Class B
Insensitivity to interference ......................................................................in accordance with EN 50082-2
Line voltage.............................................................................................................100 to 240 V ±10 %
..........................................................................................................
Change of voltage is not required!
Line frequency...................................................................................................................... 50 to 60 Hz
Power consumption of Axioskop 40 / Axioskop 40 FL ................................................................... 100 VA
Summary of Contents for Axioskop 40
Page 1: ...Operating Manual Axioskop 40 Axioskop 40 FL Routine microscope...
Page 14: ...INTRODUCTION Axioskop 40 Carl Zeiss Axioskop 40 FL 0 14 B 40 810 e 12 01...
Page 30: ...INSTRUMENT DESCRIPTION Axioskop 40 Carl Zeiss Axioskop 40 FL 1 16 B 40 810 e 12 01...
Page 77: ...Axioskop 40 OPERATION Axioskop 40 FL Carl Zeiss B 40 810 e 12 01 3 3...
Page 128: ...OPERATION Axioskop 40 Carl Zeiss Axioskop 40 FL 3 54 B 40 810 e 12 01...
Page 146: ...APPENDIX Axioskop 40 Carl Zeiss Axioskop 40 FL A 8 B 40 810 e 12 01...