GS 05P02D41-01EN Mar.14,2016-00
Ladder Sequence Function
(1) Number of I/O Points
UP35A
UP32A
Number of digital input points
Up to 8
Up to 5
Number of digital output points
Up to 8
Up to 5
This is limited by the number of contact I/O signal
points. (See the model code.)
(2) Types of Instruction
Number of
instructions
Remark
Number of basic
instruction types
13
Load, AND, OR, Timer,
Counter, etc.
Number of
application
instruction types
73
Comparison, reverse,
addition/subtraction/
multiplication/division, logic
operation, high/low limiter, etc.
(3) Sequence Device
Types of device
Number of points
Digital I/O
Input relay
8 (max)
Output relay
8 (max)
Internal device
M relay (bit data)
256
DAT register (data)
28
P register (parameter)
10
K register (constant)
30
Special device
Special relay (bit data)
12
Process data and process relay can be used
besides the above-mentioned.
(4) Program capacity
Max. Program capacity: 300 steps *
*:
Available number of steps differs according to the
parameters, using command and control period.
(5) Ladder computation period
Ladder computation period is the same as control
period.
Communication Function
Function
Method
Interface
Targets
Max connection
Communication
Data
Modbus/TCP
A standard industry
protocol allowing
communications
between the controller
and devices such as
PCs, PLCs, and DCSs.
Server
Ethernet
PLC and others
2 connections
PV, ALM etc
Gateway
Ethernet
+ RS-485
RS-485: UT75A/UT55A/
UT52A/UT35A/UT32A/
UP55A/UP35A/UM33A
(*1)
31 units
Modbus
(RTU/ASCII)
Slave
RS-485
PLC and others, UT75A/
UT55A/UT52A/UT35A/
UT32A/UP55A/UP35A/
UP32A/UM33A
(*1)
31 units
PROFIBUS-DP
Used for communication
between PLCs and
remote I/O, enabling
highspeed data
transmission.
Slave
RS-485
PLC and others
Number of nodes:
126
Modbus
master
function
RS-485
UT75A/UT55A/UT52A/
UT35A/UT32A/UP55A/
UP35A
31 Units
(Main Controller is
included.)
CC-Link
Slave
RS-485
PLC and others
Number of nodes: 42
(Remote device)
Modbus
master
function
RS-485
UT75A/UT55A/UT52A/
UT35A/UT32A/UP55A/
UP35A/UP32A/UM33A
31 Units
(Main Controller is
included.)
DeviceNet
Slave
RS-485
PLC and others
Number of nodes: 64
Modbus
master
function
RS-485
UT75A/UT55A/UT52A/
UT35A/UT32A/UP55A/
UP35A
31 Units
(Main Controller is
included.)
Peer to peer
A protocol allowing
multiple controllers to
send and receive data
between one another. The
Ladder Program is used.
Multi-drop RS-485
(2 wire
only)
UT75A/UT55A/UT52A/
UT35A/UT32A/UP55A/
UP35A/UP32A
Read/Write: 4 units
Read only : 28 units
Coordinated
Communication
A protocol to coordinate
the operation of two
or more instruments
controlling the same
process.
Master/
Slave
RS-485
UT75A/UT55A/UT52A/
UT35A/UT32A/UP55A/
UP35A/UP32A
(*2)
Master : 1 unit
Slave : 31 units
PC link
The proprietary Yokogawa
protocol allowing
communications to PCs,
PLCs and touch panels.
Slave
RS-485
UT75A/UT55A/UT52A/
UT35A/UT32A/UP55A/
UP35A/UP32A/UM33A
(*2)
31 units
Ladder
A protocol to
communicate to PLCs.
*1: UT digital indicating controller, Signal conditioner JUXTA, Power monitor POWERCERT can be connected.
*2: UT digital indication controllers can be connected.
Physical Interface
Ethernet
Standard : IEEE802.3 (10BASE-T, 100BASE-TX)
Max segment length : 100 m
Max. Connecting Configuration : Cascade Max. 4 level (10BASE-T), Max. 2 level (100BASE-TX)
RS-485
Standard: EIA RS-485
Communication method: Two-wire harf-duplex or four-wire harf-duplex, start-stop synchronization, and
non-procedural
Baud rate: 600,1200,2400,4800,9600,19200 or 38400 bps
(*3)
Peer to peer communication is fixed at 19200 bps
Maximum communication distance: 1200 m
Terminating resistor: 220Ω (External)
*3: “38400 bps” is available only for UP35A (Type 3 code = 1)
Summary of Contents for UP35A
Page 3: ......
Page 15: ...Blank Page...
Page 35: ...Blank Page...
Page 37: ...Blank Page...
Page 47: ...Blank Page...
Page 229: ...Blank Page...
Page 251: ...Blank Page...
Page 317: ...Blank Page...
Page 387: ...Blank Page...
Page 409: ...Blank Page...
Page 411: ...Blank Page...