11.3 Motion Commands
11-33
11
(9) Speed Reference (VELO)
The SVR does not support a speed control function.
(a) Operating Procedure
(b) Related Parameters
• Setting Parameters
• Monitoring Parameters
No.
Execution Conditions
Confirmation Method
1
There are no alarms.
Both IL
02 and IL
04 are 0.
2
Motion command execution has been completed.
IW
08 is 0 and IB
090 is OFF.
Execute the VELO motion command.
• Set OW
08 to 23.
The value 23 is returned to IW
08.
Execute another motion command to cancel
the speed control mode.
OW
08 = 23 (VERO)
IW
08 = 23 (VERO)
IB
090 (BUSY)
IB
098 (COMPLETE)
IB
0C0 (DEN)
IB
0C1 (POSCOMP)
IB
0C3 (PSET2)
Parameter
Name
Setting
OW
08
Motion Command
The mode is changed to speed control mode when this parameter is set to 23.
Parameter
Name
Monitor Contents
IW
08
Servo Command Type
Response
Indicates the motion command that is being executed.
The response code will be 23 during VELO command execution.