8.19 Monitor SERVOPACK Alarms (ALM_MON)
8-67
8
8.19 Monitor SERVOPACK Alarms (ALM_MON)
The ALM_MON command reads the alarm or warning that has occurred in the SERVOPACK and stores it in
Servo Alarm Code (monitoring parameter IW
2D).
(1) Operating Procedure
(2) Holding and Aborting
The Command Pause bit (OB
090) and the Command Abort bit (OB
091) cannot be used.
(3) Related Parameters
(a) Setting Parameters
No.
Execution Conditions
Confirmation Method
1
Motion command execution has been completed.
IW
08 is 0 and IB
090 is OFF.
Execute the
ALM_MON
motion command.
• Set OW
08 to 19.
• The Command Pause (OB
090) cannot be used.
• The Command Abort (OB
091) cannot be used.
Any alarms/warnings that have occurred in
the SERVOPACK are stored in the
monitoring parameter.
• IW
08 will be 19 during command
execution.
• IB
090 will be ON during command
execution.
Monitoring is completed.
• IW
08 will be 19 and IB
090 will be
OFF.
Execute NOP motion command.
• Set IW
08 to 0.
Parameter
Name
Setting
OW
08
Motion Command
Alarms are monitored when this parameter is set to 19.
OB
090
Command Pause
This parameter is ignored for ALM_MON command.
OB
091
Command Abort
This parameter is ignored for ALM_MON command.
OW
4F
Servo Alarm Monitor
Number
Set the number of the alarm to be monitored.