7 Motion Parameters
7.2.2 Motion Setting Parameter Details
7-22
OW
34
Speed Integration Time Constant
Setting Range
Setting Unit
Default Value
15 to 65535
0.01 ms
2000
The speed loop has an integral element to enable responding to minute inputs.
This element, however, causes a delay in the Servo system, adversely affecting the response if the time constant is set too
large.
The actual machine operation depends on the settings in the SERVOPACK parameters. Refer to
Appendix B.1 Parameters
Updated when a Connection is Established (MP2100/MP2100M to SERVOPACK)
for details on making parameters auto-
matically effective.
Pn109
Pn10A
Pn102
Pn101
A
B
Pn100
A
B
M
PG
Pn11F
A
B
NS100/NS115
OW
3A
(OW
32)
(OW
30)
(OW
31)
(OW
2F)
S
Kp
Ti
(OW
2E)
(OW
34)
Kv
NTi
FB
Vref
Filter
Differ-
ential
Speed
compen-
sation
Acceleration/
deceleration
processing
Acceleration: OL
36
Deceleration: OL
38
Followup
(Not supported.)
SERVOPACK
Set in a 1:1 ratio.
Current