10.3 Alarm Message List
10-37
4305
CONVERTER CIR-
CUIT CHARGE
ERROR
[Bit Pattern]
• There was no response (ready 2 signal) of
charge completed from convertor at servo
ON.
• While turning servo ON, the ready 2 signal
was intercepted.
• The ready 2 signal was not intercepted at
servo OFF (at emergency stop).
• While turning servo OFF (at emergency
stop), the ready 2 signal was turned ON.
Reasons are as follows:
• Mistaken wiring of connection for primary
side power supply.
• The drop of primary side power supply
(less than170V).
• Because the power supply cable of pri-
mary side was too fine or its cable was too
long, the voltage drop occurred at servo
ON.
• Defective WRCA01,WRCF01 circuit board
• Defective converter
• Defective amplifier (There is a possibility
that power circuit was short-circuited inter-
nally.)
• Check that primary power supply is more
than 170V.
• Replace the amplifier.
• If the error occurs again, replace the
WRCA01 circuit board, WRCF01 circuit
board, the converter.
4306
AMPLIFIER READY
SIGNAL ERROR
[Bit Pattern]
• There was no response (amp ready signal)
of energizing completed from amplifier at
servo ON.
• While turning servo ON, the amp ready
signal was intercepted.
• The amp ready signal was not intercepted
at servo OFF (at emergency stop).
• While turning servo OFF (at emergency
stop), the amp ready signal was turned
ON.
Reasons are as follows:
• Defective WRCA01,WRCF01 circuit board
• Defective converter
• Defective amplifier (There is a possibility
that power circuit was short-circuited inter-
nally.)
• Reset the alarm and turn servo ON
again.
• If the error occurs again, replace the
WRCA01 circuit board, WRCF01 circuit
board, the converter.
4307
SERVO ON DEFEC-
TIVE SPEED
Robot/Statio
[Axis Data]
• While encoder was rotating, the servo
power supply was turned on. Impossible t
turn on control power supply in the rotation
• The no brake axes, R,B,T axis for SK6,
freely fell when the servo power supply
was turned off by emergency stop. When
the servo control power supply was turned
back on this status, this alarm occurred.
Check the timing of turning on servo
power supply again.
Alarm Message List
Alarm
Number
Message
Cause
Remedy
Summary of Contents for Motoman UP6
Page 4: ...UP6 Manipulator Manual ii MOTOMAN NOTES...
Page 65: ...11 1 S Axis Parts List 11 1 11 Parts List 11 1 S Axis Parts List...
Page 67: ...11 2 L U Axis Driving Unit 11 3 11 2 L U Axis Driving Unit...
Page 69: ...11 3 R Axis Driving Unit 11 5 11 3 R Axis Driving Unit...
Page 71: ...11 4 Wrist Unit 11 7 11 4 Wrist Unit...
Page 73: ......
Page 82: ...viii...
Page 94: ...1 4 Equipment Configuration 1 12...
Page 108: ...3 8 Open Phase Check 3 8...
Page 131: ...20...
Page 146: ...xiv...
Page 147: ...Setup Diagnosis...
Page 148: ......
Page 150: ...1 2...
Page 158: ...2 1 Protection Through Security Mode Settings 2 8...
Page 256: ...3 17 File Initialize 3 98...
Page 278: ...4 2 Addition of Base and Station Axis 4 22...
Page 296: ...5 6 Position Data When Power is Turned ON OFF 5 18...
Page 297: ...Hardware...
Page 298: ......
Page 308: ...6 4 Equipment Configuration 6 10...
Page 359: ...Maintenance...
Page 360: ......
Page 368: ...8 8 Open Phase Check 8 8...
Page 388: ...9 4 Recommended Spare Parts 9 20...
Page 389: ...Alarm Error...
Page 390: ......
Page 462: ...11 1 Error Message List 11 18...
Page 463: ......
Page 466: ......
Page 530: ......
Page 531: ......
Page 533: ......
Page 534: ......
Page 535: ......
Page 536: ......
Page 537: ......
Page 538: ......
Page 539: ......
Page 540: ......
Page 541: ......
Page 542: ......
Page 543: ......
Page 544: ......
Page 545: ......
Page 546: ......
Page 547: ......
Page 548: ......
Page 549: ......
Page 550: ......
Page 551: ......
Page 552: ......
Page 553: ......
Page 554: ......
Page 555: ......
Page 556: ......
Page 557: ......
Page 558: ......
Page 559: ......
Page 560: ......
Page 561: ......