8-17
–
+
ELEC
E
STARTING SYSTEM
BATTERY
Refer to “GENERAL” in chapter 3.
FUSES
1. Check:
●
Fuse continuity
No continuity
→
Replace.
●
Fuse rating
Out of specification
→
Replace.
WIRE HARNESS
1. Check:
●
Wire harness continuity
No continuity
→
Replace.
WIRE CONNECTIONS
1. Check:
●
Wire connections
Poor connections
→
Properly con-
nect.
Fuse rating:
20 A (main fuse)
30 A (starter fuse)
STARTER RELAY
1. Check:
●
Starter relay
Faulty
→
Replace.
Checking steps:
●
Connect the tester leads between the
starter relay terminals as shown.
●
Connect the brown lead terminal to
the positive battery terminal.
●
Connect the black lead terminal to the
negative battery terminal.
●
Check that there is continuity between
the starter relay terminals.
●
Check that there is no continuity after
the brown or black lead is removed.