81
XYZ Machine Tools Ltd
TRAK
2
OP
Installation, Maintenance, Service & Part List Manual
521
Check Control IO (input/output)
Application used to check all machine input and
outputs.
Group D - Operator Defaults/Options
66
Metric Boot Up Default
To have the ProtoTRAK open up in mm measurement.
67
English Boot Up Default
To have the ProtoTRAK open up in inch
measurement.
79
Turn On Beeper
Turn the beeper on when pressing keys on the front
panel
80
Turn Off Beeper
Turn the beeper off when pressing keys
203
Initiate Homing Sequence
Homes machine
300
Set Lube Pump
Allows user to run lube pump and adjust frequency
and discharge times.
345
Set Part Program Location
Sets the location of part program storage between a
USB device and to a network
503
Set Maximum Feedrate
Sets the rapid speed for the machine. Default is 600
ipm
To access Service Codes press MODE -> RSTR -> SERV CODES followed by the Service Code group letter (A
thru D). Finally enter the required Service Code number and press ABS or INC SET.
5.11.1
Group A - Software Codes
The following codes pertain to software functions in the control. Note: If you are working with the XYZ
Customer Service Group, write the values down for Code 33. These values will be valuable for
troubleshooting.
5.11.1.1
CODE 33:
Software ID
Code 33 is the software identification procedure. This will most likely be used when a customer service
representative asks to identify what version(s) of software is being run on your machine. Code displays:
•
Software Version:
the version of the software you have installed.
•
Operating System Version: the version of the CE operating system. Hit the MORE button to
see the OS version number
5.11.1.2
CODE 141: Load Configuration File from USB flash drive
This code allows you to load your configuration file from a USB flash drive to your machine’s internal drive.
The configuration file consists of items such as calibration, backlash constants, ball lock locations, etc. This
code is useful when a computer module has been replaced, and you want to restore a machine to its
previous state.
In order to load the files correctly on the 2 OP, configuration files must be you stored in a folder called
PT8/CONFIG on the root (top level) of the thumb drive.
5.11.1.3
CODE 142: Save Configuration File to USB flash drive
This code allows you to save your configuration file to a USB flash drive. The configuration file consists of
items such as calibration, backlash constants, ball lock locations, etc. This code is used when a computer
module needs to be replaced. It is a good idea to run this code after the machine is initially setup so these
values can be saved and used in the future. If the computer fails, then you will not have the ability to save
the configuration file and the machine will need to be re-setup when the computer is replaced.
When you save the configuration file to a thumb drive, the file structure described above, in service code
141, will be created.
Summary of Contents for TRAK 2OP M11 Mill
Page 9: ...5 XYZ Machine Tools Ltd TRAK 2OP Installation Maintenance Service Part List Manual...
Page 10: ...6 XYZ Machine Tools Ltd TRAK 2OP Installation Maintenance Service Part List Manual...
Page 11: ...7 XYZ Machine Tools Ltd TRAK 2OP Installation Maintenance Service Part List Manual...
Page 12: ...8 XYZ Machine Tools Ltd TRAK 2OP Installation Maintenance Service Part List Manual...
Page 13: ...9 XYZ Machine Tools Ltd TRAK 2OP Installation Maintenance Service Part List Manual...
Page 130: ...1 14 15 1 8 15 12 15 14...