15.2.2. Read Session Parameters
The Set Read Session Parameters submenu (Figure 15.3) is used to
select options that are applied when data is released.
Note:
If the port partition has not been set, values
selected for the Source Port and Data Type options
will determine the partition location. When a Read
Session is initiated, or the Set Partition option is
selected, the partition is set according to the Source
Port and Data Type options.
1.
Source Port:
NetLink can release all data, or only data
received via a selected port. You may select PBX Port A,
PBX Port B, the AUX Port, all three, or any combination.
2.
Data Type:
Determines which type of data will be
released. The following data types may be selected:
1.
All:
Release all data from the buffer. This includes
both alarm data and non-alarm data.
2.
Standard (Non-Alarm):
Release records that did
not
match an Alarm Clue.
3.
Alarm 1 (All):
Release all data that matched any Alarm
Clue defined for Alarm Filter 1.
4.
Alarm 1 (By Clue):
Release records that matched a
specific Alarm Clue for Alarm Filter 1.
5.
Alarm 2 (All):
Release all data that matched any Alarm
Clue defined for Alarm Filter 2.
6.
Alarm 2 (By Clue):
Release records that matched a
specific Alarm Clue for Alarm Filter 2.
7.
All Alarms:
Release records that matched Alarm Filter
1
and
records that matched Alarm Filter 2.
15-8
PollCat NetLink User's Guide
SET "READ" SESSION PARAMETERS:
1.
Source Port:
All
2.
Data Type:
All
3.
Start Record:
1
4.
Record Count:
All
Enter Selection,
Press <ESC> to return to previous menu ...
Figure 15.3: Set Read Session Parameters Menu