22.
Data on ^B01:
When enabled, NetLink will immediately
begin sending data when the data release command is
invoked (Menu or ^B01). When disabled, NetLink will
send the "READY" message, then wait for Command ^B02
before releasing data. (
Default = On
).
23.
Hold "End Data":
At the end of each data release session,
NetLink will send the "End Data" message before returning
to Command Mode. When this option is enabled, this port
will wait for Command ^B02 before sending the End Data
message. (
Default = On
).
24.
Line # Tag:
Inserts a Line Number at the beginning of each
record or block released by this port. These Line Numbers
are not stored in internal memory, but are added when data
is released.
(Default = Off)
.
25.
Send Compressed:
Determines whether this port will
release data in space compressed or normal format.
(Default = Off)
.
26.
Auto Delete:
When enabled, data will be automatically
deleted from NetLink's memory at the end of each
successful read. If the read is interrupted, data will
not
be
deleted.
(Default = Off)
.
Note:
Before enabling the Auto Delete function,
please refer to the cautions listed in Section 15.7.
Output Parameters (Binary Block Mode Only):
27.
Transmit Attempts: (
Binary Mode Only) Determines how
many times this port will attempt to resend a block when
there is a transmission problem, or the connection is lost.
(Zero to 99 attempts;
Default = 3
).
28.
Transmit Delay:
(Binary Mode Only) Determines how
long this port will wait between transmit attempts. Note
that if this value is set to Zero, binary data will be sent in a
continuous block, without acknowledgment. (Zero to 99
seconds;
Default = 5 seconds
).
29.
DLE Stuffing:
(Binary Mode Only) Allows literal
characters to be inserted into binary data released by this
port.
(Default = Off)
.
4-15