page 3 – 39
AirAura X1 / Dec 2016
A i r A u r a X 1 P R O G U I
BS.412 Action (BS.412 MPX Power Control)
Adjusts the ratio between the primary and secondary timing loops. Higher
settings result in more contribution from the slower, secondary timing loop,
which also slows down increases in MPX power when it power tries to fall due
to program variations.
The control range is -6dB to 0dB. To change the control, left click on the
knob and use the mouse wheel to increase or decrease the value.
SCA 1 and SCA 2 Inputs (Subcarrier Inputs)
Inputs applied to the SCA connectors are high pass filtered to reduce hum
and then low-pass filtered at 94kHz before being digitized at 192kHz. The
SCA 1 Gain and SCA 2 Gain controls set the SCA injection levels and can be
set to OFF, or to levels between -80.0dB and +10.0dB and in 0.05dB steps.
To change the control, left click on the knob and use the mouse wheel
to increase or decrease the value.