page 3 – 46
AirAura X1 / Dec 2016
A i r A u r a X 1 P R O G U I
SYSTEM
The System screen allows system-wide settings to be configured, such as how the GUI
communicates with the hardware and security settings within the processor.
Front Panel Security Settings
Setting and clearing passwords for the front panel touchscreen is possible
from the security section of the GUI. You can choose to separately lock the
Processing-related functions and those associated with Output functions
such as stereo generator settings and output levels. Each may have its own
passcode or they may share the same passcode at the user’s discretion. The
reason for this functionality is to give stations who must cooperate with a
designated transmission authority the ability to adjust their processing in
any way they choose without giving the transmission authority access to
the processing functions. Likewise it allows the transmission authority to
manage “regulatory” things such as modulation levels, and without giving
the transmission authority access to the processing controls.
There is no default password in the X1. If you are setting this up for the
first time, you can skip the PASSWORD part and just enter the NEW PASSWORD and
VERIFY the new password.
Other options in this menu include the ability for the PC to remember the password for
the processor, to hide the password as you type it (with dots instead of the actual characters)
and the ability to gang the password for both the processing and output options. When
access is restricted, only the SYSTEM tab will be allowed to be viewed. If you try and
access another tab, you will be prompted to
input the proper password that covers the
functions in that tab.
Pressing PROCESSING PASSWORD
will bring up the screen to enter the new
processing control password.
If the X1 does not have a password, you
will be prompted to enter the password you
would like to use to lock down the process-
ing functions. Once entered, you will be
asked to verify the password selection. If
the passwords match, the X1 will indicate
the password has changed.
Repeat these steps to set or change the password for the output settings of the X1.