page 3 – 56
AirAura X1 / Dec 2016
A i r A u r a X 1 P R O G U I
O-Scope
This is a time-domain (oscilloscope-type) display of the audio at the output of the
FM and HD final peak control sections. The FM O-Scope display shows what the pre-
emphasized and clipped audio looks like. The HD path, with its more “gentle” lookahead
limiter, will appear less “aggressive” than the FM audio.
E vs. F
This display represents the RMS Loudness generated in each band of the FM or HD
Limiter as well as the peak value.
The E vs. F display has a submenu (shown right) that allows customization of the
RMS Integration Time, the display Release Rate, and
whether or not peak levels are to be displayed. The
factory default Integration Time is 300mS – the same
as a standard VU meter – which is also a fair estima
-
tor for how loud something seems to the human ear.