INSTALLATION AND OPERATION
NOTES FOR FABRICATION:
1. Use 6-inch Schedule 80 steel pipe (5.761 I.D. nominal).
2. Minimum length of seachest for standard ram hoist is 53.3 cm (21 inches).
3. Length of seachest for hydraulic hoist is 1 meter (39.4 inches). If the seachest length
is
not one meter you must talk to WESMAR prior to ordering the sonar.
4. Paint seachest inside and out with same paint system used on the hull.
5. DO NOT paint surface of flange.
6-INCH SEACHEST
IMPORTANT:
It may be necessary to
fi
le down
the
fi
ns of the soundome so that it
fi
ts into the seachest. The
clearance around the soundome
should not be greater than 1.6 mm
(1/16 inch).