4. Connections
DCR 6024/6128/6000
4 – 5
Planning and Installation –Rev. 1 / 7. 2001
4.5
TERMINAL PANEL – TAPEDECK DMS 6000
PE
PB - DATA
IN
OUT
REM 3
REM 1
OFF
Audio
TE
Video
(PE)
OFF
SIGNAL
RS 232C
REM 2
OUT
IN
REC - DATA
CONTROL
iMCS
TO PROCESSOR
AC IN
50
50
WAVE FORM MONITOR
TIME CODE
TERM
ON
OFF
TRIGGER
REMOTE
FUSE 2x T6.25A
(Rear Panel)
SMPTE TC EBU TECH3097–E
IN
AC POWER 100V to 240V with
grounding connection
Internal machine control system
Digital serial interface for remote
control panel/DCH 6024 auto editing
Grounding connection
TE Audio – Technical Grounding Audio
TE Video – Technical Grounding Video
PE Protective Grounding
SIGNAL
external osciloscope
displaying different RF– and
controltrack–signals
Bandwith > 50 MHz
TRIGGER
synchronize output for external
osciloscope
(PE) – Grounding Jack (for Service)
PLAYBACK – DATA
2 Bit parallel 8 channels ECL-level
RECORD – DATA
2 Bit parallel 8 channels ECL-level
CONTROL
Control signals for
between Tapedeck and Processor
(Timing, Reference signals)
TO PROCESSOR
Output to Processor
Input from Processor
iMCS
GROUNDING
MAINS IN
WAVE FORM MONITOR
TIME CODE
for external TC generator
OUT
from internal TC generator
IEEE 802.3
direct communication
REM 1
REMOTE
serial RS 422 ES-bus interface to
EBU TECH 3245-E
REM 2 IN/OUT
serial RS-422A interface inconformity
for editing systems (e.g. BBE)
REM 3
parallel interface SMPTE recom.
for extern control panel or
General Purpose Interface GPI
RS 232C
serial interface
for Philips service
with EIA standard
Fig. 405: Terminal panel of the Tapedeck DMS 6000
Summary of Contents for DCR 6000
Page 1: ...DCR 6024 6128 6000 MEDIA RECORDER Bild im Format 16 9 Planning Installation Manual...
Page 9: ...Safety Instructions DCR 6024 6128 6000 IV Planning Installation Rev 1 7 2001...
Page 17: ...1 General DCR 6024 6128 6000 1 8 Planning and Installation Rev 1 7 2001...
Page 21: ...1 General DCR 6024 6128 6000 1 12 Planning and Installation Rev 1 7 2001...
Page 41: ...1 General DCR 6024 6128 6000 1 32 Planning and Installation Rev 1 7 2001...
Page 53: ...2 Technical Specifications DCR 6024 6128 6000 2 12 Planning and Installation Rev 1 7 2001...
Page 83: ...4 Connections DCR 6024 6128 6000 4 6 Planning and Installation Rev 1 7 2001...
Page 95: ...4 Connections DCR 6024 6128 6000 4 18 Planning and Installation Rev 1 7 2001...
Page 105: ...4 Connections DCR 6024 6128 6000 4 28 Planning and Installation Rev 1 7 2001...
Page 137: ...6 Interfaces DCR 6024 6128 6000 6 18 Planning and Installation Rev 1 7 2001...
Page 143: ...7 DTV Applications DCR 6024 6128 6000 7 6 Planning and Installation Rev 1 7 2001...
Page 148: ...9 Index DCR 6024 6128 6000 9 3 Planning and Installation Rev 1 7 2001...
Page 149: ...9 Index DCR 6024 6128 6000 9 4 Planning and Installation Rev 1 7 2001...