4. Connections
DCR 6024/6128/6000
4 – 10
Planning and Installation – Rev. 1 / 7. 2001
4.5.1.2
MAINS CONNECTION
AC IN
AC IN
Fuse
FUSE 2x T 6.25A / 250V
Fig. 409: AC Power IN of the Tapedeck
For the mains connection of the DMS 6000 Tapedeck, the mains cord is connected
to the mains connection socket (AC IN). The mains cord is included in the shipment.
Main fuses on connector panel:
2x T6.25 A / 250V slow, UL-listed (valid for the entire voltage range 100 - 240 V).
Caution!
Double-pole or neutral fusing. Risk of electric shock. Grounded circuit con-
ductor (neutral) provided with over-current protection. After operation of the
protective device, parts of the equipment that remain under voltage might
represent a hazard during servicing. Disconnect power before servicing!
The Tapedeck and the Processors include a wide-range power supply unit of 100
- 240V so that no changeover is required for different line voltages.
AC IN
Fuses
Changing of power
supply voltage
Summary of Contents for DCR 6000
Page 1: ...DCR 6024 6128 6000 MEDIA RECORDER Bild im Format 16 9 Planning Installation Manual...
Page 9: ...Safety Instructions DCR 6024 6128 6000 IV Planning Installation Rev 1 7 2001...
Page 17: ...1 General DCR 6024 6128 6000 1 8 Planning and Installation Rev 1 7 2001...
Page 21: ...1 General DCR 6024 6128 6000 1 12 Planning and Installation Rev 1 7 2001...
Page 41: ...1 General DCR 6024 6128 6000 1 32 Planning and Installation Rev 1 7 2001...
Page 53: ...2 Technical Specifications DCR 6024 6128 6000 2 12 Planning and Installation Rev 1 7 2001...
Page 83: ...4 Connections DCR 6024 6128 6000 4 6 Planning and Installation Rev 1 7 2001...
Page 95: ...4 Connections DCR 6024 6128 6000 4 18 Planning and Installation Rev 1 7 2001...
Page 105: ...4 Connections DCR 6024 6128 6000 4 28 Planning and Installation Rev 1 7 2001...
Page 137: ...6 Interfaces DCR 6024 6128 6000 6 18 Planning and Installation Rev 1 7 2001...
Page 143: ...7 DTV Applications DCR 6024 6128 6000 7 6 Planning and Installation Rev 1 7 2001...
Page 148: ...9 Index DCR 6024 6128 6000 9 3 Planning and Installation Rev 1 7 2001...
Page 149: ...9 Index DCR 6024 6128 6000 9 4 Planning and Installation Rev 1 7 2001...