6. Interfaces
DCR 6024/6128/6000
6 – 7
Planning and Installation – Rev. 1 / 7. 2001
CMD1 assigns the command to the following main function groups which serve to
define the function and the transfer direction of the data words which follows (see
table below):
CMD 1
Function
Transfer direction
Control system DCR 6024
0
System control
------->
1
System control - return message
<-------
2
Tape deck control
------->
4
Setup and selection control
<-------
8
Data request
------->
7
Data request return message
<-------
Defines the number of the data words which are inserted after CMD2 (0 to F hex).
Is the specific command to the DCR 6024 or the command return message from
the DCR 6024, respectively.
The number of data words and their contents are defined by the CMD2 command.
The sum of the data (D0 to D7) contained in each data word i.e. from CMD1/DATA
COUNT up to the last data word before the checksum. The Checksum is used to
verify that the data are error free and makes sure that transmission sequences
which are affected by bit errors are rejected.
The interface of DCR 6024 uses a 9-pin female subminiature D connector whose
pin out is shown in the table below.
REM 2 IN – RS 422A
Pin-No.
Signal
1
Ground
2
Transmit A
1
3
Receive B
9
1
4
Ground
6
5
5
Not used
5
9 pole D type
6
Ground
9 pole D-type
female
7
Transmit B
8
Receive A
9
Ground
Fig. 603: Pin assignment remote 2 IN
CMD 1
Data count
CMD 2
DATA
CHECKSUM
Connector pin
assignment
Summary of Contents for DCR 6000
Page 1: ...DCR 6024 6128 6000 MEDIA RECORDER Bild im Format 16 9 Planning Installation Manual...
Page 9: ...Safety Instructions DCR 6024 6128 6000 IV Planning Installation Rev 1 7 2001...
Page 17: ...1 General DCR 6024 6128 6000 1 8 Planning and Installation Rev 1 7 2001...
Page 21: ...1 General DCR 6024 6128 6000 1 12 Planning and Installation Rev 1 7 2001...
Page 41: ...1 General DCR 6024 6128 6000 1 32 Planning and Installation Rev 1 7 2001...
Page 53: ...2 Technical Specifications DCR 6024 6128 6000 2 12 Planning and Installation Rev 1 7 2001...
Page 83: ...4 Connections DCR 6024 6128 6000 4 6 Planning and Installation Rev 1 7 2001...
Page 95: ...4 Connections DCR 6024 6128 6000 4 18 Planning and Installation Rev 1 7 2001...
Page 105: ...4 Connections DCR 6024 6128 6000 4 28 Planning and Installation Rev 1 7 2001...
Page 137: ...6 Interfaces DCR 6024 6128 6000 6 18 Planning and Installation Rev 1 7 2001...
Page 143: ...7 DTV Applications DCR 6024 6128 6000 7 6 Planning and Installation Rev 1 7 2001...
Page 148: ...9 Index DCR 6024 6128 6000 9 3 Planning and Installation Rev 1 7 2001...
Page 149: ...9 Index DCR 6024 6128 6000 9 4 Planning and Installation Rev 1 7 2001...