Footnote 15
The SERVO REFERENCE SELECT data is defined as:
01H: external analog ref
02H: video input
FFH: as selected locally
Footnote 18
The TIMER MODE SELECT data is defined as:
00H: LTC
01H: TT1
02H: TT2
FFH: as defined locally
Footnote19
The EDIT- FIELD SELECT data is defined as:
00H: edit starts every field depending start of edit command
01H: edit starts in field 1
02H: edit starts in field 2
FFH: as selected locally
Footnote 20
The FREEZE MODE SELECT data is defined as:
00H: field freeze
11H: frame freeze
Footnote 21
The TC GEN DATA SENSE data is defined as:
01H: request generator timecode
response=74H, 08H, 4 byte BCD timecode
10H: request generator userbits
response=74H, 09H, 4 byte userbits
11H: request generator ub + tc
response=78H, 08H, 8 byte BCD tc + ub
Footnote 22
The CURRENT TIME SENSE data is defined as:
T8 Bit 1 = ON
01H:
request LTC tc
response = 74H, 04H, 4 byte LTC
or
response = 74H, 14 H, 4 byte corr. LTC
03H:
request LTC tc
response = 74H, 04H, 4 byte LTC
or
response = 74H, 06H, 4 byte VITC
04H:
request timer 1
response = 74H, 00H, 4 byte timer data
08H:
request timer 2
response = 74H, 01H, 4 byte timer data
10H:
request LTC userbits
response = 74H, 15H, 4 byte userbits
11H:
request LTC tc + ub
response = 78H, 04H, 8 byte LTC tc + ub
T8 Bit 1 = OFF
01H:
request LTC tc
response=74H, 04H, 4 byte LTC
or
response=74H, 14 H, 4 byte corr. LTC
02H:
request ASTC tc
response= 74H, 06H,4 byte ASTC
03H:
request LTC/ASTC tc response=74H, 04H, 4 byte LTC
or
response=74H, 06H, 4 byte ASTC
04H:
request timer 1
response=74H, 00H, 4 byte timer data
08H:
request timer 2
response=74H, 01H, 4 byte timer data
10H:
request LTC userbits
response=74H, 15H, 4 byte userbits
20H:
req ASTC userbits
response=74H, 00H, 4 byte timer data
11H:
request LTC tc + ub
response=78H, 04H, 8 byte LTC tc + ub
33H:
req LTC/ATC tc+ub
response=78H, 04H, 8byte LTC tc+ub
or
response=74H, 06H,8 byte ASTC tc+ub
Footnote 23
There is a field-ID in the LTC-TIME-Data:
60Hz/Data 2
50Hz/Data 4
Field
MSB
MSB
Selection
0
0
Field 1
1
1
Field 2
Summary of Contents for DCR 6000
Page 1: ...DCR 6024 6128 6000 MEDIA RECORDER Bild im Format 16 9 Planning Installation Manual...
Page 9: ...Safety Instructions DCR 6024 6128 6000 IV Planning Installation Rev 1 7 2001...
Page 17: ...1 General DCR 6024 6128 6000 1 8 Planning and Installation Rev 1 7 2001...
Page 21: ...1 General DCR 6024 6128 6000 1 12 Planning and Installation Rev 1 7 2001...
Page 41: ...1 General DCR 6024 6128 6000 1 32 Planning and Installation Rev 1 7 2001...
Page 53: ...2 Technical Specifications DCR 6024 6128 6000 2 12 Planning and Installation Rev 1 7 2001...
Page 83: ...4 Connections DCR 6024 6128 6000 4 6 Planning and Installation Rev 1 7 2001...
Page 95: ...4 Connections DCR 6024 6128 6000 4 18 Planning and Installation Rev 1 7 2001...
Page 105: ...4 Connections DCR 6024 6128 6000 4 28 Planning and Installation Rev 1 7 2001...
Page 137: ...6 Interfaces DCR 6024 6128 6000 6 18 Planning and Installation Rev 1 7 2001...
Page 143: ...7 DTV Applications DCR 6024 6128 6000 7 6 Planning and Installation Rev 1 7 2001...
Page 148: ...9 Index DCR 6024 6128 6000 9 3 Planning and Installation Rev 1 7 2001...
Page 149: ...9 Index DCR 6024 6128 6000 9 4 Planning and Installation Rev 1 7 2001...