6. Interfaces
DCR 6024/6128/6000
6 – 11
Planning and Installation – Rev. 1 / 7. 2001
Footnote 0
xx = data -1
yy = data -2
This ID can be set via the RS232 diagnostics interface.
Default
data -1 = 00
data -2 = E0
For 50 Hz field rate version the LSB of data -1 is always set to ”1” automatically
Footnote 1
This function is limited to - 0.25 ... 0.25 times PLAY speed.
Footnote 2
The low resolution speed data consists of one byte (Value = 0 ... 255).
The real tape speed in multiples of play is defined as
Tape Speed = 10
(value/32-2)
This means, the speed data is the logarithmic translation of the tape speed.
(eg. value = 32 : 0.1 x play, value = 64 : 1 x play, value = 96 : 10 x play)
Footnote 3
The speed range from -0.25 .... 0.25 times PLAY speed is executed as VARIABLE. The ranges above
and below are executed as SHUTTLE to allow synchronization of the machine with this command.
Footnote 4
The high resolution speed data consists of two bytes, but only the first data byte is used to calculate the
tape speed (refer to footnote 2).
Footnote 5
The parking accuracy depends on the parking accuracy value set on the Control Panel.
Footnote 6
The Timecode data consists of 4 byte coded in BCD:
data 1 :
Frames
data 2 :
Seconds
data 3 :
Minutes
data 4 :
Hours
Footnote 7
The command allows synchronization of the machine. The argument (0 ... 255) is a deviation (0 %
... 25,5 %) to 1 x PLAY speed in steps of 0,1 %
DEVIATION (%) = 0,1% x SPEED DATA
Footnote 8
The time base for this operation can be set with the TAPE CODE SELECT command.
Footnote 9
The operation is done with the selected tracks and record mode of the EDIT PRESET command.
Footnote 10
The IN- and OUT-point must be set before with IN/OUT ENTRY or IN/OUT DATA PRESET command.
Footnote 11
If the servo is not locked this command will be executed as a FULL EE ON to allow to do BVB (BLACK-
VIDEO-BLACK) simulation.
Footnote 12
The user bits data consists of 4 byte (high nibble/low nibble):
data 1 : binary group 2 / binary group 1
data 2 : binary group 4 / binary group 3
data 3 : binary group 6 / binary group 5
data 4 : binary group 8 / binary group 7
Summary of Contents for DCR 6000
Page 1: ...DCR 6024 6128 6000 MEDIA RECORDER Bild im Format 16 9 Planning Installation Manual...
Page 9: ...Safety Instructions DCR 6024 6128 6000 IV Planning Installation Rev 1 7 2001...
Page 17: ...1 General DCR 6024 6128 6000 1 8 Planning and Installation Rev 1 7 2001...
Page 21: ...1 General DCR 6024 6128 6000 1 12 Planning and Installation Rev 1 7 2001...
Page 41: ...1 General DCR 6024 6128 6000 1 32 Planning and Installation Rev 1 7 2001...
Page 53: ...2 Technical Specifications DCR 6024 6128 6000 2 12 Planning and Installation Rev 1 7 2001...
Page 83: ...4 Connections DCR 6024 6128 6000 4 6 Planning and Installation Rev 1 7 2001...
Page 95: ...4 Connections DCR 6024 6128 6000 4 18 Planning and Installation Rev 1 7 2001...
Page 105: ...4 Connections DCR 6024 6128 6000 4 28 Planning and Installation Rev 1 7 2001...
Page 137: ...6 Interfaces DCR 6024 6128 6000 6 18 Planning and Installation Rev 1 7 2001...
Page 143: ...7 DTV Applications DCR 6024 6128 6000 7 6 Planning and Installation Rev 1 7 2001...
Page 148: ...9 Index DCR 6024 6128 6000 9 3 Planning and Installation Rev 1 7 2001...
Page 149: ...9 Index DCR 6024 6128 6000 9 4 Planning and Installation Rev 1 7 2001...