4. Connections
DCR 6024/6128/6000
4 – 29
Planning and Installation – Rev. 1 / 7. 2001
4.7.1
AC POWER TERMINAL
AC IN
PE
POWER
1
0
TE
Fig. 429: AC power terminal unit of the Processor
4.7.1.1
GROUNDING
The Processor is to be connected to ground according to VDE 0800/part 2 and/or
the applicable national regulations. The protective conductor must always be con-
nected before the unit is connected to the mains.
The Processor has separate protective (PE) and functional (TE) grounds. Their ter-
minals are located at the rear.
PE
TE
Fig. 430: Grounding connector of the Processor
The enclosure of the Processor is always connected to the protective ground (PE)
conductor.
The machine is supplied with the PE and TE grounding terminals bridged.
GROUNDING CONNECTIONS
TE
PE
Summary of Contents for DCR 6000
Page 1: ...DCR 6024 6128 6000 MEDIA RECORDER Bild im Format 16 9 Planning Installation Manual...
Page 9: ...Safety Instructions DCR 6024 6128 6000 IV Planning Installation Rev 1 7 2001...
Page 17: ...1 General DCR 6024 6128 6000 1 8 Planning and Installation Rev 1 7 2001...
Page 21: ...1 General DCR 6024 6128 6000 1 12 Planning and Installation Rev 1 7 2001...
Page 41: ...1 General DCR 6024 6128 6000 1 32 Planning and Installation Rev 1 7 2001...
Page 53: ...2 Technical Specifications DCR 6024 6128 6000 2 12 Planning and Installation Rev 1 7 2001...
Page 83: ...4 Connections DCR 6024 6128 6000 4 6 Planning and Installation Rev 1 7 2001...
Page 95: ...4 Connections DCR 6024 6128 6000 4 18 Planning and Installation Rev 1 7 2001...
Page 105: ...4 Connections DCR 6024 6128 6000 4 28 Planning and Installation Rev 1 7 2001...
Page 137: ...6 Interfaces DCR 6024 6128 6000 6 18 Planning and Installation Rev 1 7 2001...
Page 143: ...7 DTV Applications DCR 6024 6128 6000 7 6 Planning and Installation Rev 1 7 2001...
Page 148: ...9 Index DCR 6024 6128 6000 9 3 Planning and Installation Rev 1 7 2001...
Page 149: ...9 Index DCR 6024 6128 6000 9 4 Planning and Installation Rev 1 7 2001...