1. General
DCR 6024/6128/6000
1 – 25
Planning and Installation – Rev. 1 / 7. 2001
The scanner power supply board BY 5112 contains the following functions:
1. Two switch mode power supplies (+5V and –12V/–7V) for the scanner record-
and play-back amplifiers.
2. Thermal protection of record amplifiers by detecting the headwheel rotation.
If the rotation speed of the headwheel goes down, the record mode is cut off.
This prevents thermal damages of the record amplifiers.
3. Erase oscillator (30 MHz) for the flying erase heads.
4. Head switch logic realized by a FPGA.
The FPGA generates all the timing signals for the record and play process in
the RF- path as well as EE information for the Processor in simulation mode.
5. Processing of waveform monitoring signals.
iMCS
The control system of the recorder DCR 6024 is conceived as a multi Processor
system.The main components of the control system are connected via the serial
iMCS bus system with each other ( iMCS = internal machine communication sys-
tem). This bus is based on standard IEEE 802.3 (ETHERNET). Because of the
cable deviating from the ETHERNET-Standard, the bus system is confessed also
under name CHEAPERNET. The maximal cable length is specified with 185m.
The participants in the iMCS system are:
Tapedeck / System Control Unit BY 5160
Control Panel DCH 6024 CP
DTV Processor / System Control Unit SYSC
Data processor / System Control Unit DPCU
Up to four DCR 6024 can be controlled within one iMCS net. Individual recorder
station addresses can be set up by local address switches, see chapter 5.3
”Startup”.
The system control board BY 5160 is divided into two sections, BY 5161 and
BY 5162.
The overall function can be separated into seven main groups:
Central Control Unit
CCU
Gateway (Serial I/O Unit)
GW
Timecode Unit
TCU
Motor Control Unit
MCU
Digital Motor Control
DMC
Clock Generator
RF & Sensor Evaluation
Scanner Power
supply
Control System
Summary of Contents for DCR 6000
Page 1: ...DCR 6024 6128 6000 MEDIA RECORDER Bild im Format 16 9 Planning Installation Manual...
Page 9: ...Safety Instructions DCR 6024 6128 6000 IV Planning Installation Rev 1 7 2001...
Page 17: ...1 General DCR 6024 6128 6000 1 8 Planning and Installation Rev 1 7 2001...
Page 21: ...1 General DCR 6024 6128 6000 1 12 Planning and Installation Rev 1 7 2001...
Page 41: ...1 General DCR 6024 6128 6000 1 32 Planning and Installation Rev 1 7 2001...
Page 53: ...2 Technical Specifications DCR 6024 6128 6000 2 12 Planning and Installation Rev 1 7 2001...
Page 83: ...4 Connections DCR 6024 6128 6000 4 6 Planning and Installation Rev 1 7 2001...
Page 95: ...4 Connections DCR 6024 6128 6000 4 18 Planning and Installation Rev 1 7 2001...
Page 105: ...4 Connections DCR 6024 6128 6000 4 28 Planning and Installation Rev 1 7 2001...
Page 137: ...6 Interfaces DCR 6024 6128 6000 6 18 Planning and Installation Rev 1 7 2001...
Page 143: ...7 DTV Applications DCR 6024 6128 6000 7 6 Planning and Installation Rev 1 7 2001...
Page 148: ...9 Index DCR 6024 6128 6000 9 3 Planning and Installation Rev 1 7 2001...
Page 149: ...9 Index DCR 6024 6128 6000 9 4 Planning and Installation Rev 1 7 2001...