7. DTV Applications
DCR 6024/6128/6000
7 – 4
Planning and Installation – Rev. 1 / 7. 2001
7.4
PARAMETER SHEET BVE 9000
For each DCR 6024 connected to the editor BVE 9000 the following parameters
have to be set for the according VTR-port (SETUP/IDC/MACHINE PARAMETER
GROUP) at the initial installation.
It is recommended to install these parameters at all ports to ensure correct
machine control on all ports if other configurations are used (e.g. RS-422 router).
BLOCK
BYTE
Name
Value
Remarks
1
1
2
DEV-TYPE
01 / 00H
EOH
DCR 6024 identification
01H at 50 Hz
00H at 60 Hz
1
3
4
MIN PREROLL
TIME
00H
64H / 78H
64H at 50H
78H at 60H
1
5
EDIT DELAY
05H
1
6
EE DELAY
05H
1
7
OVERRUN
05H
1
8
TRAJECTORY CON.
1FH
2
1
TC READ DELAY
0FH
2
2
START DELAY
07H
2
3
AFTER SYNC DEL–
FFH
2
4
AFTER SYNC DEL+
00H
2
5
CONST 11
01H
2
6
CONST 12
64H
2
7
PREROLL SPEED
FFH
2
8
QUICK PVW PR TIME
4BH / 5AH
4BH at 50 Hz
5AH at 60 Hz
3
1
A1 ASSIGN
08H
3
2
A2 ASSIGN
09H
3
3
A3 ASSIGN
0AH
3
4
A4 ASSIGN
0BH
4
1
MODE
01H
Setup-Parameter for
Editing-Systems
BVE 9000
(Software Version 2)
Summary of Contents for DCR 6000
Page 1: ...DCR 6024 6128 6000 MEDIA RECORDER Bild im Format 16 9 Planning Installation Manual...
Page 9: ...Safety Instructions DCR 6024 6128 6000 IV Planning Installation Rev 1 7 2001...
Page 17: ...1 General DCR 6024 6128 6000 1 8 Planning and Installation Rev 1 7 2001...
Page 21: ...1 General DCR 6024 6128 6000 1 12 Planning and Installation Rev 1 7 2001...
Page 41: ...1 General DCR 6024 6128 6000 1 32 Planning and Installation Rev 1 7 2001...
Page 53: ...2 Technical Specifications DCR 6024 6128 6000 2 12 Planning and Installation Rev 1 7 2001...
Page 83: ...4 Connections DCR 6024 6128 6000 4 6 Planning and Installation Rev 1 7 2001...
Page 95: ...4 Connections DCR 6024 6128 6000 4 18 Planning and Installation Rev 1 7 2001...
Page 105: ...4 Connections DCR 6024 6128 6000 4 28 Planning and Installation Rev 1 7 2001...
Page 137: ...6 Interfaces DCR 6024 6128 6000 6 18 Planning and Installation Rev 1 7 2001...
Page 143: ...7 DTV Applications DCR 6024 6128 6000 7 6 Planning and Installation Rev 1 7 2001...
Page 148: ...9 Index DCR 6024 6128 6000 9 3 Planning and Installation Rev 1 7 2001...
Page 149: ...9 Index DCR 6024 6128 6000 9 4 Planning and Installation Rev 1 7 2001...