background image

Quick System Setup

Install and Cable LED Wall 

— Ensure that your FLX 

LED wall is properly installed and cabled.

1

Rackmount DX-100 

— Ensure that the DX-100 is 

properly installed in your equipment rack.  
(Chapter 3, “Rack-Mount Installation”)

2

5

6

P/N 26-0901004-00, Rev 00

Quick Start Guide

Visibly yours

Barco, Inc.

11101 Trade Center Drive
Rancho Cordova, CA 
95670 • USA

Phone:

Fax:

Technical Support: 

Website:

+1 (916) 859-2500
+1 (916) 859-2515
+1 (866) 374-7878
www.barco.com

Power Installation 

— Connect power to the DX-100 

and all peripheral equipment, such as your video 
sources.  (Chapter 3, “Power Installation”)

Connect Inputs 

— As required, connect inputs to the 

DX-100's 

DVI 

and 

SD/HD-SDI 

inputs.  (Chapter 3, 

“Signal Installation”)

7

8

Power On 

— Turn on power to the DX-100, sources, 

the LED wall and (if required) Fiberlink.   

9

10

3

4

The following list summarizes the 
overall DX-100 setup procedure.  For 
error-free installation, always refer to 
the listed section in the User’s Guide.  

DX-100

Status

Handles

Two recessed handles 

enable you to easily 

insert or withdraw the 

chassis from a rack.  

Status LED

The following indications are provided:

On power up, the LED initializes to Orange, and 
remains Orange while the DX-100 boots.  The 
LED also turns orange during any “reset” mode.

The LED turns Green once the DX-100 can be 
controlled remotely.

The LED blinks Red (at a 2 second interval) if the 
DX-100 detects that the FLX controller is drawing 
too much current. 

IMPORTANT

There are no operational controls 

on the DX-100.  The DX-100 is set 

up and operated entirely from 

Barco’s 

Director Toolset

.  

Connect Output 

— Connect the DX-100's NNI LED 

output to the data input of the FLX LED wall.  
(Chapter 3, “Signal Installation”)

Connect Genlock 

— Connect a composite sync or 

black burst signal to the 

Genlock In 

connector.  

(Chapter 3, “Signal Installation”)

Connect Director Toolset 

— Connect your laptop 

PC to DX-100 via Ethernet.  Ensure that 

Director 

Toolset 

is properly installed on the laptop.  

(Chapter 3, “Signal Installation”)

Connect Fiberlink 

— If required, connect the 

Fiberlink NNI transmitter and receiver.  (Appendix C, 
“Installation”)

System Operation 

— Use 

Director Toolset 

for all 

DX-100 setup and operations.  Refer to the 

Director 

Toolset User’s Guide 

for instructions.  

IMPORTANT

Director Toolset 

version 2.03 or 

higher is required.

Reviews: