Soak and clean the inside of the reservoir with a Clorox type solution if needed to remove
scale buildup. Rinse the reservoir with clean water, return the level indicator to a vertical
position and refill. Replace cover and ensure that the pump electrical cable and the water
feeding hose are positioned in the cut out provided in the cover.
Cleaning the vice rail and lead screw
Make sure that the vise locking screws are loose and press the “Shift” key.
Hold down the left arrow key to open the vise wide enough to expose as much of the vise
lead screw as possible. Inspect the vise lead screw for any debris build up and clean using
a paint brush and alcohol if needed. Apply a light layer silicon lubricant on the lead screw.
Partially close the vise by holding down the “right” arrow key to access the ends of the lead
screw and repeat the procedure.