209
PCB 2, terminal strip X8
Pos.
Function
Explanation
Terminals
End of safety chain
'Live' in case of fault-free safety
chain
2X8.1
Compressor control via
EEV controller (refrigerant
circuit control)
■ Heat demand: Contact closed,
2X8.2 is 'live'
■ If the compressor will not start,
check whether it has been ena-
bled by the EEV controller (own
relay on EEV PCB, see
page 217)
Internal connection
2X8.1
2X8.2
N/A
N/A
2X8.3
2X8.4
Fan control
Internal connection
2X8.5
w¢E
Secondary pump
■ In systems without a heating
water buffer cylinder, no other
heating circuit pump is required
(see terminal 2X7.9)
■ Max. output: 130 W
On-site connection
2X8.7
w¢R
Control of instantaneous
heating water heater,
stage 1
Accessories
■ Output 10 W
On-site connection
2X8.8
w¢T
Control of the mixer motor,
heating circuit M2, signal
OPEN
■ 230 V
On-site connection
2X8.9
w¢Z
Control of the mixer motor,
heating circuit M2, signal
CLOSED
■ 230 V
On-site connection
2X8.10
w¢U
Heating circuit pump of the
heating circuit with mixer
M2
■ Max. output: 100 W
On-site connection
2X8.11
Connection and wiring diagrams
Overview of the PCBs and connection options
(cont.)
5414 828 GB
Service
Summary of Contents for VITOCAL 350-A
Page 54: ...54 5 3x 7 6 3x 3x 3x Installation sequence Fitting the outer panels cont 5414 828 GB ...
Page 58: ...58 2x 10 11 3x 3x Installation sequence Fitting the outer panels cont 5414 828 GB ...
Page 62: ...62 Type AWH I 1 Installation sequence Installing the heat pump cont 5414 828 GB ...
Page 228: ...228 052 054 059 008 056 025 020 Parts lists Parts list type AWH I cont 5414 828 GB ...
Page 236: ...236 053 032 039 034 038 033 034 039 027 Parts lists Parts list type AWH O cont 5414 828 GB ...
Page 237: ...237 052 054 059 008 055 025 020 Parts lists Parts list type AWH O cont 5414 828 GB Service ...