64
Note
■ In underfloor heating circuits, integrate
a temperature limiter on site for limiting
the maximum temperature of under-
floor heating systems.
■ Integrate an overflow valve in every
heating circuit (excl. single pipe heat-
ing circuits) to safeguard the minimum
flow rate (see specification on
page 246).
■ Equip the secondary circuit on site with
an expansion vessel.
Type AWH-I
1.
2.
3.
1.
Push heating water return/DHW cyl-
inder return
C
onto connection and
secure with both plug-in connector
retainers.
2.
Push heating water flow/DHW cylin-
der flow
A
onto connection and
secure with both plug-in connector
retainers.
Installation sequence
Connecting the heating circuits and condensate drain
5414 828 GB