111
1X3.7
1X3.6
C
B
A
H
D
F
E
5
4
3
3
4
4
3
3/N
3/N
≈
4
G
kWh
kWh
Shown excluding fuses and RCD
A
Heat pump control unit
B
Instantaneous heating water heater
(accessory)
C
Compressor
D
High tariff meter
E
Ripple control receiver (contact
open: power-OFF enabled)
F
Backup fuse ripple control receiver
G
TNC system feed
H
Low tariff meter
Power-OFF with on-site load discon-
nection
The power-OFF signal is connected to
the on-site contactor of the low tariff
power supply and in the heat pump con-
trol unit. The compressor
and
instanta-
neous heating water heater (accessory)
are "forced" off when power-OFF is ena-
bled.
Note
Observe the technical connection condi-
tions of the relevant power supply util-
ity.
Installation sequence
Power supply
(cont.)
5414 828 GB