16
Dimensions
Type AWH-I
a
b
c
110
489
367
880
114
489
217
1030
120
472
64
1200
Cables (for installation see from page 68)
A
C
D
G
E
H
F
K
B
A
Heat pump control unit
Wall outlet for cables: central,
directly below the heat pump control
unit
B
Power cable for heat pump control
unit 230 V/50 Hz
Recommended cable: 3 x 1.5 mm
2
C
Power cables for further compo-
nents and functions:
■ Pumps/pump control
■ Mixer
■ Sensors
■ Auxiliary functions (power-OFF,
external blocking, external
demand, external heat source
control, etc.)
■ Fault message
■ Two-way shut-off valve
■ Communication facilities
■ KM BUS
■ Remote control
D
Two connecting cables, fully wired
(5, 15 or 30 m):
■
Control cable
230 V~
■
Low voltage cable
< 42 V
Preparing for installation
Internal heat pump, type AWH-I
(cont.)
5414 828 GB