246
Vitocal 350-A
Type
AWH-I
AWH-O
110
114
120
110
114
120
Output data
to
DIN EN 14511 (2/35 °C,
5 K spread)
Rated heating output
kW
10.6
14.5
18.5
10.6
14.5
18.5
Power consumption
kW
3.0
4.2
5.8
3.0
4.2
5.8
Coefficient of perform-
ance
∊
(COP)
3.5
3.5
3.2
3.5
3.5
3.2
Output data
to
DIN EN 14511
(7/35 °C)
Rated heating output
kW
12.7
16.7
20.6
12.7
16.7
20.6
Power consumption
kW
3.1
4.4
6.1
3.1
4.4
6.1
Coefficient of perform-
ance
∊
(COP)
4.1
3.8
3.4
4.1
3.8
3.4
Primary circuit
Fan rating
W
110
170
270
110
170
270
Air volume
m
3
/h
3500
4000
4500
3500
4000
4500
Max. permiss. pressure
drop
(on the ventilation and
extract air side of air
ducts)
Pa
37
45
61
—
—
—
Min. air temperature
°C
–20
–20
–20
–20
–20
–20
Max. air temperature
°C
35
35
35
35
35
35
Proportion defrost time/
runtime
%
2 to 5
2 to 5
2 to 5
2 to 5
2 to 5
2 to 5
Heating water
(secon-
dary circuit)
Capacity
l
5.0
5.5
6.0
5.0
5.5
6.0
Minimum flow rate
(always maintain)
l/h
920
1250
1520
920
1250
1520
Pressure drop (with con-
nection pipes supplied in
standard delivery)
mbar
20
35
45
20
35
45
Max. flow temperature
at -20°C outside temper-
ature
°C
55
55
55
55
55
55
Max. flow temperature
at -10°C outside temper-
ature
°C
65
65
65
65
65
65
Specification
Specification
(cont.)
5414 828 GB
Summary of Contents for VITOCAL 350-A
Page 54: ...54 5 3x 7 6 3x 3x 3x Installation sequence Fitting the outer panels cont 5414 828 GB ...
Page 58: ...58 2x 10 11 3x 3x Installation sequence Fitting the outer panels cont 5414 828 GB ...
Page 62: ...62 Type AWH I 1 Installation sequence Installing the heat pump cont 5414 828 GB ...
Page 228: ...228 052 054 059 008 056 025 020 Parts lists Parts list type AWH I cont 5414 828 GB ...
Page 236: ...236 053 032 039 034 038 033 034 039 027 Parts lists Parts list type AWH O cont 5414 828 GB ...
Page 237: ...237 052 054 059 008 055 025 020 Parts lists Parts list type AWH O cont 5414 828 GB Service ...