171
Menu
■
"Device settings"
■
"Programming"
■
"System definition"
■
"Cascade control"
Delivered condition
0
Setting
0 / 1 / 2
Number of lag heat pumps
Number of lag heat pumps in a cascade that are connected via LON or via external
extension H1.
Note
Parameter "Cascade control" on the
lead appliance must be set to "1" (for
control via external extension H1) or
"2" (for control via LON).
"0"
No lag heat pump
"1"
up to
"3"
Number of lag heat pumps for con-
trol via external extension H1
"1"
up to
"4"
Number of lag heat pumps for con-
trol via LON
Menu
■
"Device settings"
■
"Programming"
■
"System definition"
■
"No. of external heat pumps"
Delivered condition
0
Setting
0 / 1 / 2 / 3 / 4
Number of lag heat pumps in a cascade that are connected via external extension
H1.
Note
Parameter "Cascade control" on the
lead appliance must be set to "1".
"0"
No lag heat pump
"1"
up to
"3"
Number of lag heat pumps for con-
trol via external extension H1
Menu
■
"Device settings"
■
"Programming"
■
"System definition"
■
"No. of external heat pumps"
Delivered condition
0
Setting
0 / 1 / 2 / 3 / 4
System definition control settings
Cascade
(cont.)
5414 828 GB
Service
Summary of Contents for VITOCAL 350-A
Page 54: ...54 5 3x 7 6 3x 3x 3x Installation sequence Fitting the outer panels cont 5414 828 GB ...
Page 58: ...58 2x 10 11 3x 3x Installation sequence Fitting the outer panels cont 5414 828 GB ...
Page 62: ...62 Type AWH I 1 Installation sequence Installing the heat pump cont 5414 828 GB ...
Page 228: ...228 052 054 059 008 056 025 020 Parts lists Parts list type AWH I cont 5414 828 GB ...
Page 236: ...236 053 032 039 034 038 033 034 039 027 Parts lists Parts list type AWH O cont 5414 828 GB ...
Page 237: ...237 052 054 059 008 055 025 020 Parts lists Parts list type AWH O cont 5414 828 GB Service ...