background image

Operation of the Air Purifier KA-520 

Use the master switch 

 to switch on the unit. The unit always starts up in operating stage I in timed 

mode.

 

The operating stage (air volume) is adjusted using buttons 

 and 

 on the rear of the unit. You can 

choose from two factory pre-set operating stages (air volumes): 

Press button 

 briefly: Operating stage I starts up. Status indicator 

 turns green. 

Press button 

 briefly: Operating stage II starts up. Status indicator 

 turns green. 

 
 

 

 

1.

 

Mains power connection using cable supplied 

2.

 

Master switch 

3.

 

Button for operating stage II 

4.

 

Button for operating stage I 

5.

 

Status indicator for operation at stage I 

6.

 

Status indicator for operation at stage II 

7.

 

Filter indicator 

8.

 

Dial for timer stage II (30-180 minutes can be selected) 

 
 

 

Operating stage I 

Operating stage II 

Air volume 

Sound pressure 

level 

Air volume 

Sound pressure 

level 

KA-520 XL 

200 m³/h 

44 dB(A) 

700 m³/h 

64 dB(A) 

KA-520 XL Pro 

330 m³/h 

39 dB(A) 

675 m³/h 

50 dB(A) 

KA-520 XXL 

580 m³/h 

37 dB(A) 

1030 m³/h 

48 dB(A) 

KA-520 XXL Pro 

880 m³/h 

44 dB(A) 

1640 m³/h 

56 dB(A) 

 

Operating stage I in timed mode:

 Press button 

 briefly. Status indicator 

 turns green. The unit runs for 

12 hours and then switches automatically to standby mode. Pressing button 

 again restarts the unit and 

it runs again for 12 hours. This avoids continuous operation of the unit (e.g. operation overnight). 

Operating stage I in continuous mode:

 Press and hold down button 

 until the status indicator 

 flashes. 

The unit now runs continuously until it is switched off again manually. 

Operating stage II in timer mode:

 Press button 

 briefly. Status indicator 

 turns green. The unit now 

runs for a period of 30 – 180 minutes, which can be adjusted using the dial 

. At the end of this period, 

the unit switches to operating stage I and timed mode. 

Operating stage II in continuous mode:

 Press and hold down button 

 until the status indicator 

 flashes. 

The unit now runs continuously until it is switched off again manually. 

Video on the operation of the air purifier KA-520: 

https://l.ka-520.de/bedienung 

 

Reviews: