background image

Filter indicator 

The filter indicator 

 signals the following 3 statuses to the user: 

1. Filter indicator is off:

-

Filter status is OK. 

2. Filter indicator flashes (after approx. 750 operating hours):

-

Re-order filter (remaining operating time = 50 hours). 

3. Filter indicator is lit continuously (after approx. 800 operating hours):

-

Replace the filter immediately. The unit can only operate in operating stage II. 

A filter change needs to be confirmed using buttons 

 and 

-

Press and hold down buttons 

 and 

 until status indicators 

 and 

 flash green once.

o

The filter indicator has been reset (OFF), the unit runs in operating stage I (timed mode).

A sticker explaining the basic functions is attached to the unit beside the control panel: 

Operating stage

Filter display

Operation time 12 h:

-  Press  button;  display 

lights up continuously.

Continuous operation:

- Hold button down until 

display light flashes. 

Timer:

- Press button; display lights 

up continuously.

Continuous operation:

- Hold button down until 

display light flashes. 

Timer setting

OFF:

-  Filter status OK

 

Flashing:

-  Reorder filter

Continuous light:

- Change filter*

Level II:

- Adjustable from 30 - 

180 minutes**

Level I:

- Not adjustable, 

switches off after 12 

hours

** When the timer 

has expired, the 

device switches from 

level II to level I and 

switches off after 12 

hours.

Video filter change:

Video operation:

*Press operating stage buttons  I and II simultaneously for 5 seconds to confirm 

filter change.