Machine Stop Malfunction
Jam Condition does
not cause Machine
Stop
M1
Red Jam
Indicator lit
during Jam
?
yes
no
Jam condition does not exist.
Machine stops
after Jam
Condition
?
no
yes
Control is functioning properly.
Relay LED lit
during Jam
Condition
?
no
yes
1. Check wiring from Machine Interface
connector to Machine Stop circuit.
2. Replace 151xx404 Machine
Interface board.
Is this a
VC3700
?
no
yes
1. Check cable wiring from 151xx410
Glue Inspection board J1 to 151xx404
Machine Interface board J1.
2. Replace 151xx410 Glue Inspection
board.
Is MSTOP
Indicator lit on
151xx410
?
no
yes
For VC3700:
1. Check minimum speed setting.
2. Check ribbon cable from 151xx362
CPU board J4 to 151xx410 Glue
Inspection board J10.
3. Check seating of U9, U10, U11 on
151xx410 Glue Inspection board.
4. Replace 151xx410 Glue Inspection
board.
For VC3500:
1. Check minimum speed setting.
2. Check wiring from 151xx366
Interface board J6 to 151xx404
Machine Interface board J3.
3. Replace 151xx366 Interface board.