Is Scanner
cable correctly
terminated
inside control?
Correct the terminations inside control.
1. Replace Scanner and/or
2. Replace 151xx366 Interface Board.
yes
no
See Manual for correct terminations.
help
(cont.)
S2
Is 12v I/O
lamp on front
panel on?
1. Check connections at J7 of 151xx366
Interface board.
2. Check connections at J5 of 151xx368
Power Supply board.
The symbol for this light is an arrow enteing a box.
help
no
no
yes
yes
Is DMM
available for
measuring
voltages?
S3
Is LED D3 of
151xx368
Power Supply
board on?
1. Check fuse F2 on 151xx368 Power
Supply board.
2. Check connectiions at J1 of 151xx368
Power Supply board.
3. Replace 151xx368 Power Supply
board.
yes
no
Go to Scanner Light Malfunction
page (S3) to make further
checks on Encoder.
help
G1
Scanner Light Malfunction
Go to Glue Absence page (G1)
to repeat checks.