Initial Setup
VC3500 User’s Manual
Valco Cincinnati
42
Specify Minimum Gluing Speed
To specify the minimum gluing speed, follow these steps:
1. Begin operating the production line at the desired minimum speed (the speed at which gluing will begin).
2. Press the “MIN SPEED” button in the level-3 menu screen.
Note!
The minimum speed setting screen displays two bar graphs. The top bar graph displays the minimum
speed of the parent machine at which gluing will begin. The bottom bar graph displays the actual
speed of the parent machine. The maximum speed indication of the bar graph is 1000 feet (300
meters) per minute. If the parent machine exceeds this speed, the bar graph restarts from the left side
and displays the speed above 1000 feet (300 meters) per minute.
3. Use the plus or minus buttons on the screen to adjust the upper bar graph (minimum speed) so that it is less
than the lower bar graph (actual machine speed).
4. Press the “EXIT” button when done.
Set Cell-to-Gun Dimensions
To set the cell-to-gun dimensions, follow these steps:
1. Press the “CELL-GUN 1” button in the level-3 menu screen. The cell-to-gun setting screen displays.
2. Using the numeric keypad, enter the distance between the channel 1 scanner and the channel 1 glue valve
(this value will display in either inches or millimeters depending on the setup of your control).
Note!
Each channel (valve) has a separate cell-to-gun setting (“CELL-GUN 1” and
“CELL-GUN 2”).
3. Press the “ENTER” button. The “OK DONE” message displays, indicating that the distance entered has
been saved.
Note
!
This value should need no adjustment after the initial installation of the control and valves. However,
the setting should be checked if the valves or scanners are moved or changed.
4. Press the “EXIT” button to return to the level-3 menu screen.
Note!
To set additional cell-to-gun dimensions, you repeat steps 4a. through 4d.
Specify Ratio Compensation
To specify ratio compensation, follow these steps:
1. Press the “RATIO COMP” button in the level-4 menu screen.
2. Set the ratio compensation either manually or automatically (see procedures below).
Manual Ratio Compensation
To set ratio compensation manually, follow these steps:
1. Press the “RATIO COMP” button in the level-4 menu screen. The ratio compensation screen displays.
2. Using the numeric keyboard, input the number of encoder pulses per inch (25.4 mm) of product line travel.
3. Press the “ENTER” button. (The “OK DONE” message displays.)
Summary of Contents for VC3500
Page 1: ...VC3500 User s Manual Software Version 3 X Manual Number MCO35 Manual Release Date July 1999 ...
Page 19: ...Installation VC3500 User s Manual Valco Cincinnati 16 Figure 8 Internal Connections Diagram ...
Page 88: ...VC3700 User s Manual Software Version 3 X Manual Number MCO34 Manual Release Date July 1999 ...
Page 181: ...VC3500 VC3700 Troubleshooting Manual Manual Number MC048 Release Date May 1999 ...
Page 185: ...VC3500 VC3700 Troubleshooting Manual Valco Cincinnati Page 1 System Level Documents ...