Capacitive Glue Sensor Adjustment
To adjust the capacitive glue sensor, follow these steps:
1. Apply a glue pattern to the product.
2. Observe the LED on top of the sensor (Figure 16) while glue is within sensor’s field of view.
3.
If the LED is illuminated:
3a. Turn the adjustment screw counterclockwise until the light goes off.
3b. Turn the adjustment screw clockwise until the LED comes on.
3c. Turn the adjustment screw clockwise an additional 1/2 turn.
4.
If the LED is not illuminated:
4a. Turn the adjustment screw clockwise until the LED comes on.
4b. Turn the adjustment screw clockwise an additional 1/2 turn.
UV Sensor
Mechanical Installation
The UV glue pattern detection sensor is an optical, electronic sensor. It is used to detect fluorescent objects (such as
UV liquid added to glue) optically and without contact.
To install the UV sensor, follow these steps:
1. Mount the sensor onto the guide bracket so that its sensing surface is approximately 1 inch (25mm) above the
glue line being sensed.
2. Adjust the guiding bars so that the product has the least horizontal and vertical movement. Pay attention to the
scanning range when adjusting the bars.
3. Connect the cable to the plug receptacle on the glue sensor.
Electrical Installation
The cables used to connect the glue sensors to the control should have a minimum of three conductors (18–22
AWG) and a shield.
To connect the glue sensor to the control, follow these steps:
1. Insert the glue sensor cables into the control enclosure through the cord grip located on the bottom panel of the
control.
2. Connect the glue sensor cables to J7 (glue 1) or J8 (glue 2) on the glue inspection logic board (see Figure 8).
Connections are as follows:
Pin 1: 12VDC
Pin 2: Glue sensor signal input
Pin 3: Return
3. Connect shield wire to the protective earth (P.E.) terminals located near the cord-grip base plate.
4. Tighten the cord grips used by the glue sensor cables.
UV Sensor Time Delay Setting
The time-delay switch must be set to “0”.
Summary of Contents for VC3500
Page 1: ...VC3500 User s Manual Software Version 3 X Manual Number MCO35 Manual Release Date July 1999 ...
Page 19: ...Installation VC3500 User s Manual Valco Cincinnati 16 Figure 8 Internal Connections Diagram ...
Page 88: ...VC3700 User s Manual Software Version 3 X Manual Number MCO34 Manual Release Date July 1999 ...
Page 181: ...VC3500 VC3700 Troubleshooting Manual Manual Number MC048 Release Date May 1999 ...
Page 185: ...VC3500 VC3700 Troubleshooting Manual Valco Cincinnati Page 1 System Level Documents ...