VC3500/VC3700 Troubleshooting Manual
Valco Cincinnati
Page 15
Interface board - 151xx366
(Reference Schematic 999xD151-202)
Service Access Points
Connectors
CO1
Connection to LED board via a 30 pin ribbon cable.
CO2
Connection to CPU board via a 26 pin ribbon cable.
CO3
Connection to Valve Driver board(s) via a 20 pin ribbon cable.
J1, J2, J3, J4
Connection for product scanners.
J5
Connection for encoder.
J6
Connection for Machine Interface Board for machine stop relay.
J7
Connection for 17 VDC supply voltage from the Power Supply board.
J8
Connection for dump-valve (glue by-pass valve).
Replacement Fuses
Function Label
Type
Value
Valco
Number
12vdc I/O Supply
F1
PC Mount
1.5A
085xx132
Dump Valve Active
F2
PC Mount
1.5A
085xx132
Indicators
D1 (12V)
When lit, this green LED indicates that the 12vdc supply for scanners,
encoder, and by-pass valve (dump valve) is operational.
D2
When lit, this yellow LED indicates that the by-pass valve is activated
and that the parent machine is above minimum speed.
Jumpers
JP1 & JP2
Valve Driver Type
Pins 1 & 2 jumpered: Use of 151xx367 Valve Driver Board.
Pins 2 & 3 jumpered: Future use.
JP3
Future
Pins 2 & 3 jumpered: Normal.
JP4
Future
Pins 2 & 3 jumpered: Normal.
Schematic Description
Ground Reference
The ground reference used on this board for encoder and scanner inputs is isolated from
other grounds used in the system. Opto-isolators on the Interface board provide this
isolation.
Summary of Contents for VC3500
Page 1: ...VC3500 User s Manual Software Version 3 X Manual Number MCO35 Manual Release Date July 1999 ...
Page 19: ...Installation VC3500 User s Manual Valco Cincinnati 16 Figure 8 Internal Connections Diagram ...
Page 88: ...VC3700 User s Manual Software Version 3 X Manual Number MCO34 Manual Release Date July 1999 ...
Page 181: ...VC3500 VC3700 Troubleshooting Manual Manual Number MC048 Release Date May 1999 ...
Page 185: ...VC3500 VC3700 Troubleshooting Manual Valco Cincinnati Page 1 System Level Documents ...