Basic Features
VC3700 User’s Manual
Valco Cincinnati
9
7
Glue inspection indicator light
(items 7a through 7d are status indicator lights)
7a
Product scanner
This light illuminates to indicate the start of the glue inpsection process. It remains illuminated as long as
the product is being sensed.
7 b
Glue sensor
This light illuminates when the glue sensor detects the glue.
7c
PASS
This light illuminates briefly if the glue line on the previous product
is
within the tolerance specified in the
glue-QC setup screen. Intermittent, rapid flashing of the PASS light means that the control
cannot deter-
mine if the
glue line on the previous product is within the tolerance specified in the glue-QC setup screen.
7 d
FAIL
This light illuminates briefly if the glue line on the previous product is
not
within the
tolerance specified in the glue-QC setup screen.
Bottom Panel Features
The following are descriptions of the features on the bottom panel (Figure 2).
1
Air exhaust output
This output is for air to exhaust to atmosphere. It is not normally connected.
2
Air input
Input for regulated air, 80-100 psi (6.5–8 bar).
3
Computer interface
DB-9 socket for optional RS232 communications (standard DTE)
4
Air output
This output is connected to the glue regulator to provide speed-dependent glue pressure.
5
Optional machine interface
(items 5a and 5b are machine interface connectors)
5a
Beacon/horn connector
See the “Installation” section for wiring details.
5 b
Machine interface relay connector
See the “Installation” section for wiring details.
6
Power module
This main power supply connection uses an IEC standard line cord (supplied). The fuse drawer in this
module provides fuses for both sides of the main supply and selection of either 115 or 230VAC. The on/
off switch for the control is also located on this module.
Note!
Ensure that the proper fuse configuration for the power source is installed. See the “Installation” section
for details.
7
Line cord clamp
Two clamps are included in the installation kit. One clamp fits the included European line cord and the
other clamp fits the included North American line cord. The two 4-40 x 3/8" screws should be used to
attach the clamp to the enclosure.
Summary of Contents for VC3500
Page 1: ...VC3500 User s Manual Software Version 3 X Manual Number MCO35 Manual Release Date July 1999 ...
Page 19: ...Installation VC3500 User s Manual Valco Cincinnati 16 Figure 8 Internal Connections Diagram ...
Page 88: ...VC3700 User s Manual Software Version 3 X Manual Number MCO34 Manual Release Date July 1999 ...
Page 181: ...VC3500 VC3700 Troubleshooting Manual Manual Number MC048 Release Date May 1999 ...
Page 185: ...VC3500 VC3700 Troubleshooting Manual Valco Cincinnati Page 1 System Level Documents ...