Valco Cincinnati
73
Specifications
Control Dimensions
Height:
19.55” (497mm)
Depth:
5.6” (142mm)
Width:
13.44” (341mm)
Input voltage:
115/230VAC, 2/1A, 50/60Hz (field-switchable)
Scanners
Inputs:
One per channel
Type/voltage:
NPN/sinking/12VDC
Configuration:
Independent for each channel or one linked to channels 1 and 2
Valve Outputs
Channels:
Two, one valve per channel
Peak voltage:
+56V, 1–10ms adjustable (maximum 600W instantaneous per channel, not to
exceed 10% duty cycle)
Hold voltage:
+5V to +12V, adjustable
Encoder
Inputs:
One (40kHz maximum)
Type/voltage:
VCE-1000 recommended, 12VDC
Miscellaneous
Maximum gluing speed:
2000 feet (610m) per minute
Maximum glue length:
99.99” (2539mm)
Flow control:
Internal (EPC-6)
Maximum glue pressure:
100 psi (7 bar)
Job storage capacity:
99 jobs
Glue patterns:
One or two per channel
Scanner lockout function:
Internal
Jam preventer function:
Internal
Computer hardware
interface:
RS-232 (optional) DB-9 socket, standard DTE
Machine interface relay:
One normally open and one normally closed contact, 24VDC, 24`VAC, 2A
Introduction
This section contains specifications for the VC3700 control.
Summary of Contents for VC3500
Page 1: ...VC3500 User s Manual Software Version 3 X Manual Number MCO35 Manual Release Date July 1999 ...
Page 19: ...Installation VC3500 User s Manual Valco Cincinnati 16 Figure 8 Internal Connections Diagram ...
Page 88: ...VC3700 User s Manual Software Version 3 X Manual Number MCO34 Manual Release Date July 1999 ...
Page 181: ...VC3500 VC3700 Troubleshooting Manual Manual Number MC048 Release Date May 1999 ...
Page 185: ...VC3500 VC3700 Troubleshooting Manual Valco Cincinnati Page 1 System Level Documents ...