Glue Volume Malfunction
Glue Volume is too
light or too heavy
Stop Machine
Does
air guage
vary 30-60
psi?
Run machine at half
speed without
product
Adjust T-handle glue
regulator to 10 -15
psi.
Does air
pressure
change with
speed?
Vary machine speed
no
yes
With glue hose disconnected from
the glue valve, glue should exit hose
smoothly at 1 to 2 cups per minute.
help
X1
Go to EPC Adjustment page
(X1) to adjust the Electronic
Pressure Control board.
help
yes
no
G1
1. Check for a clogged glue valve.
2. Replace air assist MAC valve.
3. Replace glue valve.
Use Glue Pressure
+/-toggle switch to
determine limits of
pressure adjustment
Is
air guage
attached to
output air port
?
yes
no
Y1
Go to Analog Board
Adjustment page (Y1) to adjust
the pressure bar graph on LCD
display.
help