Appendix B
VC3700 User’s Manual
Valco Cincinnati
90
To redraw the front screen, follow these steps:
1. Send 254.
2. Wait for ACK.
3. Send 0,0,0,0,100 (to redraw the front screen).
To set channel 1 turn-on compensation to 5.5ms, follow these steps:
1. Send 254.
2. Wait for ACK.
3. Send 0,0,5,5,21.
To set ratio compensation to 98.5 pulses, follow these steps:
1. Send 254.
2. Wait for ACK.
3. Send 0,9,8,5,30.
Receiving Information from VC3700
Receive information is required to update a secondary machine user interface, such as that found on a parent
machine control.
The data is requested by the host computer, using the following format:
1. Send receive-request byte (from host).
Receive-request byte = 253dec.
2. Receive ACK byte (from VC3700).
3. Send location code (from host).
4. Receive Byte 4, Byte 3, Byte 2, Byte 1 (from VC3700).
Example of Receiving Data
To display the first glue pattern length, follow these steps:
1. Send 253.
2. Wait for ACK.
3. Send 2.
4. Receive b4,b3,b2,b1.
Note!
The measurement mode of the VC3700 control needs to be determined by the host in order for the
host to display the information in inch or metric mode.
Note!
When switching between the inch and metric modes via the RS232 link, the data is not converted
accurately.
Summary of Contents for VC3500
Page 1: ...VC3500 User s Manual Software Version 3 X Manual Number MCO35 Manual Release Date July 1999 ...
Page 19: ...Installation VC3500 User s Manual Valco Cincinnati 16 Figure 8 Internal Connections Diagram ...
Page 88: ...VC3700 User s Manual Software Version 3 X Manual Number MCO34 Manual Release Date July 1999 ...
Page 181: ...VC3500 VC3700 Troubleshooting Manual Manual Number MC048 Release Date May 1999 ...
Page 185: ...VC3500 VC3700 Troubleshooting Manual Valco Cincinnati Page 1 System Level Documents ...