Installation
VC3700 User’s Manual
Valco Cincinnati
21
Electrical Installation of Scanner
The cable used to connect the scanner(s) to the VC3700 control should have a minimum of three conductors (18-22
AWG) and a shield.
To connect the scanner to the control, follow these steps:
1. Insert the scanner cable into the control enclosure through a cord grip located on the bottom panel of the
control.
2. Connect the scanner cable to one of the three-terminal connectors labeled “scanner-1” and “scanner-2.
Note!
The “scanner-1” connector must be used for the scanner installed for channel 1. This scanner can also
be used to control channel 2. If separate scanners are desired to control channel 1 and channel 2, the
“scanner-1” connector must be used for the scanner installed for channel 1, and the “scanner-2”
connector must be used for the scanner installed for channel 2. Connections are as follows (see Figure
8 for wire colors):
Pin 1:
+12VDC
Pin 2:
Scanner signal
Pin 3:
Return
3. Connect shield wire(s) to the protective earth (P.E.) terminals located near cord-grip base plate.
4. Tighten the cord grip used by the scanner cable (s).
Glue Valve Installation
Electrical Installation of Glue Valve
The glue valve cable should have a minimum of two conductors (18-20 AWG) and a shield (four conductors and a
shield if a remote purge is required).
To connect the glue valve to the control, follow these steps:
1. Insert the glue valve cable into the control through a cord grip located on the bottom panel of the control.
2. Connect glue valve cable to the connectors labeled “valve-1” or “valve-2.”
Note!
The “valve-1” connector must be used for the glue valve controlled by channel 1. The “valve-2”
connector must be used for the glue valve controlled by channel 2 (see the Internal Connections
diagram). Connections are as follows (see Figure 8 for wire colors):
Pin 1: Purge output
Pin 2: Purge return
Pin 3: Valve output
Pin 4: Valve return
3. The shield wire should be connected to the protective earth (P.E.) terminals located near the cord grip base
plate.
4. Tighten the cord grip used by the valve cable.
Summary of Contents for VC3500
Page 1: ...VC3500 User s Manual Software Version 3 X Manual Number MCO35 Manual Release Date July 1999 ...
Page 19: ...Installation VC3500 User s Manual Valco Cincinnati 16 Figure 8 Internal Connections Diagram ...
Page 88: ...VC3700 User s Manual Software Version 3 X Manual Number MCO34 Manual Release Date July 1999 ...
Page 181: ...VC3500 VC3700 Troubleshooting Manual Manual Number MC048 Release Date May 1999 ...
Page 185: ...VC3500 VC3700 Troubleshooting Manual Valco Cincinnati Page 1 System Level Documents ...